Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.187 kW
05/17/2025 06:05 (1816 days) Production Consumption NET Usage
Now 0.078 kW 0.265 kW 0.187 kW
Today 0.014 kWh (0.002 kW) 2.209 kWh (0.361 kW) 2.195 kWh (0.358 kW)
  - This Week 108.517 kWh (17.350 kWh/day) 89.872 kWh (14.369 kWh/day) -18.645 kWh (-2.981 kWh/day)
  - This Month 290.273 kWh (17.858 kWh/day) 228.664 kWh (14.068 kWh/day) -61.609 kWh (-3.790 kWh/day)
  - This Year 2.114 MWh (15.512 kWh/day) 2.037 MWh (14.953 kWh/day) -0.076 MWh (-0.559 kWh/day)
Yesterday 14.791 kWh (0.617 kW) 12.895 kWh (0.538 kW) -1.896 kWh (-0.079 kW)
Last 7 Days 141.044 kWh (20.152 kWh/day) 107.376 kWh (15.342 kWh/day) -33.668 kWh (-4.810 kWh/day)
Last 30 Days 641.482 kWh (21.383 kWh/day) 460.022 kWh (15.335 kWh/day) -181.460 kWh (-6.049 kWh/day)
Last One Year 6.676 MWh (18.291 kWh/day) 6.268 MWh (17.173 kWh/day) -0.408 MWh (-1.118 kWh/day)
Lifetime Since PTO 31.564 MWh (17.379 kW/day) 33.989 MWh (18.714 kW/day) 2.425 MWh (1.335 kW/day)
Lifetime Since Install 31.598 MWh 34.569 MWh 2.971 MWh
Voltage/Current 251.9 V / 0.3 A 251.8 V / 1.1 A 251.9 V / 0.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/26/2023 23:53 (13.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 24.805 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.300 1.630 1.505 12.014 0.000 kW
1.596 kWh
0.000 kW
9.574 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.570 1.414 11.465
03 - 202224****** IQ7+M [5] VCOP 0.000 0.300 1.621 1.474 11.864
04 - 202232****** IQ7+ [5] VCOP 0.000 0.299 1.631 1.504 12.026
05 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.532 1.292 11.082
06 - 202245****** IQ7+M [5] VCOP 0.000 0.302 1.589 1.406 11.558
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.300 1.633 1.362 11.641 0.000 kW
1.621 kWh
0.000 kW
8.105 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.300 1.584 1.329 11.536
09 - 202217****** IQ7+ [5] VCOP 0.000 0.300 1.592 1.335 11.519
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.635 1.389 11.708
11 - 202224****** IQ7+M [5] VCOP 0.000 0.300 1.661 1.427 11.933
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.278 1.334 1.488 10.342 0.000 kW
1.386 kWh
0.000 kW
5.544 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.286 1.346 1.514 10.554
14 - 202216****** IQ7+ [5] VCOP 0.000 0.286 1.431 1.574 10.948
15 - 202245****** IQ7+M [5] VCOP 0.000 0.289 1.434 1.574 10.929
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.234 1.582 1.580 11.597 0.000 kW
1.582 kWh
0.000 kW
1.582 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.75 V Current/Power -1.29 A (-68 W)
Remain Capacity/Energy 292.2 Ah (15.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 48.7 % State Of Health 100.0 %
Run Time 9d 10h 30m to empty Report Date 2023-04-26 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.