Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.456 kW
05/17/2025 12:48 (1816 days) Production Consumption NET Usage
Now 4.000 kW 0.544 kW -3.456 kW
Today 9.345 kWh (0.728 kW) 6.259 kWh (0.488 kW) -3.086 kWh (-0.240 kW)
  - This Week 117.848 kWh (18.035 kWh/day) 93.922 kWh (14.374 kWh/day) -23.926 kWh (-3.662 kWh/day)
  - This Month 299.604 kWh (18.120 kWh/day) 232.714 kWh (14.075 kWh/day) -66.890 kWh (-4.046 kWh/day)
  - This Year 2.123 MWh (15.548 kWh/day) 2.041 MWh (14.952 kWh/day) -0.081 MWh (-0.597 kWh/day)
Yesterday 14.791 kWh (0.617 kW) 12.895 kWh (0.538 kW) -1.896 kWh (-0.079 kW)
Last 7 Days 141.044 kWh (20.152 kWh/day) 107.376 kWh (15.342 kWh/day) -33.668 kWh (-4.810 kWh/day)
Last 30 Days 641.482 kWh (21.383 kWh/day) 460.022 kWh (15.335 kWh/day) -181.460 kWh (-6.049 kWh/day)
Last One Year 6.676 MWh (18.291 kWh/day) 6.268 MWh (17.173 kWh/day) -0.408 MWh (-1.118 kWh/day)
Lifetime Since PTO 31.574 MWh (17.381 kW/day) 33.993 MWh (18.713 kW/day) 2.420 MWh (1.332 kW/day)
Lifetime Since Install 31.608 MWh 34.573 MWh 2.966 MWh
Voltage/Current 250.6 V / 16.0 A 250.6 V / 2.2 A 250.6 V / -13.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/11/2023 22:52 (8.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.627 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.114 0.398 0.163 3.368 0.000 kW
0.384 kWh
0.000 kW
2.302 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.111 0.371 0.152 3.212
03 - 202224****** IQ7+M [5] VCOP 0.000 0.115 0.396 0.163 3.370
04 - 202232****** IQ7+ [5] VCOP 0.000 0.113 0.390 0.158 3.320
05 - 202244****** IQ7+M [5] VCOP 0.000 0.112 0.374 0.151 3.257
06 - 202245****** IQ7+M [5] VCOP 0.000 0.111 0.374 0.154 3.235
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.126 0.381 0.145 3.347 0.000 kW
0.381 kWh
0.000 kW
1.905 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.126 0.385 0.146 3.653
09 - 202217****** IQ7+ [5] VCOP 0.000 0.127 0.378 0.145 3.831
10 - 202244****** IQ7+M [5] VCOP 0.000 0.127 0.385 0.147 3.805
11 - 202224****** IQ7+M [5] VCOP 0.000 0.127 0.377 0.145 3.602
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.078 0.347 0.160 1.962 0.000 kW
0.355 kWh
0.000 kW
1.419 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.082 0.360 0.159 2.107
14 - 202216****** IQ7+ [5] VCOP 0.000 0.083 0.359 0.166 2.124
15 - 202245****** IQ7+M [5] VCOP 0.000 0.081 0.353 0.159 2.063
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.83 V Current/Power -1.65 A (-87 W)
Remain Capacity/Energy 384.6 Ah (19.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 64.1 % State Of Health 100.0 %
Run Time 9d 17h 5m to empty Report Date 2023-01-11 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.