Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.125 kW
03/21/2026 23:05 (2124 days) Production Consumption NET Usage
Now 0.317 kW 0.192 kW -0.125 kW
Today 25.242 kWh (1.093 kW) 14.153 kWh (0.613 kW) -11.089 kWh (-0.480 kW)
  - This Week 138.979 kWh (19.961 kWh/day) 132.469 kWh (19.026 kWh/day) -6.510 kWh (-0.935 kWh/day)
  - This Month 373.700 kWh (17.827 kWh/day) 336.496 kWh (16.052 kWh/day) -37.204 kWh (-1.775 kWh/day)
  - This Year 1.008 MWh (12.601 kWh/day) 1.436 MWh (17.962 kWh/day) 0.429 MWh (5.361 kWh/day)
Yesterday 19.934 kWh (0.831 kW) 13.045 kWh (0.544 kW) -6.889 kWh (-0.287 kW)
Last 7 Days 139.254 kWh (19.893 kWh/day) 132.902 kWh (18.986 kWh/day) -6.352 kWh (-0.907 kWh/day)
Last 30 Days (02/19/2026) 468.364 kWh (15.612 kWh/day) 458.411 kWh (15.280 kWh/day) -9.953 kWh (-0.332 kWh/day)
Last One Year 6.079 MWh (16.654 kWh/day) 7.893 MWh (21.624 kWh/day) 1.814 MWh (4.971 kWh/day)
Lifetime Since PTO 36.573 MWh (17.211 kW/day) 40.947 MWh (19.270 kW/day) 4.374 MWh (2.058 kW/day)
Lifetime Since Install 36.607 MWh 41.527 MWh 4.920 MWh
Voltage/Current 250.7 V / 1.3 A 250.5 V / 0.8 A 250.6 V / -0.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/10/2023 23:56 (17.1 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 12.124 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.199 0.766 0.907 9.704 0.000 kW
0.746 kWh
0.000 kW
4.477 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.189 0.728 0.865 9.222
03 - 202224****** IQ7+M [0] ---- 0.000 0.195 0.759 0.896 9.577
04 - 202232****** IQ7+ [0] ---- 0.000 0.200 0.759 0.901 9.673
05 - 202244****** IQ7+M [0] ---- 0.000 0.190 0.720 0.857 8.962
06 - 202245****** IQ7+M [0] ---- 0.000 0.193 0.745 0.885 9.225
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.209 0.770 0.867 9.355 0.000 kW
0.774 kWh
0.000 kW
3.871 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.214 0.774 0.872 9.632
09 - 202217****** IQ7+ [0] ---- 0.000 0.211 0.770 0.867 9.523
10 - 202244****** IQ7+M [0] ---- 0.000 0.206 0.776 0.871 9.644
11 - 202224****** IQ7+M [0] ---- 0.000 0.209 0.781 0.879 9.800
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.141 0.588 0.770 7.995 0.000 kW
0.619 kWh
0.000 kW
2.478 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.147 0.609 0.798 8.122
14 - 202216****** IQ7+ [0] ---- 0.000 0.150 0.640 0.823 8.413
15 - 202245****** IQ7+M [0] ---- 0.000 0.154 0.641 0.825 8.415
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
0.649 kWh
0.230 kW
1.298 kWh
17 - 122214****** IQ7PD [0] ---- 0.230 0.230 1.298 3.852 16.470
Panel Layout Each Group Production

Battery History
Voltage 52.54 V Current/Power -6.27 A (-0.329 kW)
Remain Capacity/Energy 309.9 Ah (15.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 52.3 % State Of Health 98.9 %
Run Time 2d 1h 25m to empty Report Date 2023-09-10 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.