Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.775 kW
10/26/2025 10:25 (1978 days) Production Consumption NET Usage
Now 2.006 kW 0.231 kW -1.775 kW
Today 2.006 kWh (0.192 kW) 2.238 kWh (0.214 kW) 0.232 kWh (0.022 kW)
  - This Week 2.006 kWh (4.614 kWh/day) 2.238 kWh (5.148 kWh/day) 0.232 kWh (0.534 kWh/day)
  - This Month 413.092 kWh (16.241 kWh/day) 427.178 kWh (16.795 kWh/day) 14.086 kWh (0.554 kWh/day)
  - This Year 5.512 MWh (18.471 kWh/day) 6.282 MWh (21.050 kWh/day) 0.770 MWh (2.580 kWh/day)
Yesterday 12.292 kWh (0.512 kW) 0.960 kWh (0.040 kW) -11.332 kWh (-0.472 kW)
Last 7 Days 99.996 kWh (14.285 kWh/day) 119.150 kWh (17.021 kWh/day) 19.154 kWh (2.736 kWh/day)
Last 30 Days 503.497 kWh (16.783 kWh/day) 522.962 kWh (17.432 kWh/day) 19.465 kWh (0.649 kWh/day)
Last One Year 6.247 MWh (17.115 kWh/day) 7.446 MWh (20.400 kWh/day) 1.199 MWh (3.285 kWh/day)
Lifetime Since PTO 34.963 MWh (17.672 kW/day) 38.234 MWh (19.325 kW/day) 3.271 MWh (1.653 kW/day)
Lifetime Since Install 34.997 MWh 38.814 MWh 3.817 MWh
Voltage/Current 256.4 V / 7.8 A 256.3 V / 0.9 A 256.3 V / -6.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/29/2023 23:27 (12.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.738 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.299 1.999 0.987 7.447 0.000 kW
1.942 kWh
0.000 kW
11.652 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.918 0.939 7.107
03 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.996 0.982 7.420
04 - 202232****** IQ7+ [5] VCOP 0.000 0.301 2.015 0.978 7.432
05 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.849 0.934 6.912
06 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.876 0.953 7.035
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 1.886 0.986 7.029 0.000 kW
1.997 kWh
0.000 kW
9.984 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.299 2.009 0.988 7.393
09 - 202217****** IQ7+ [5] VCOP 0.000 0.300 1.995 0.962 7.383
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 2.036 1.004 7.460
11 - 202224****** IQ7+M [5] VCOP 0.000 0.300 2.058 1.009 7.519
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.226 1.585 0.780 5.954 0.000 kW
1.647 kWh
0.000 kW
6.588 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.231 1.624 0.824 6.200
14 - 202216****** IQ7+ [5] VCOP 0.000 0.236 1.690 0.865 6.508
15 - 202245****** IQ7+M [5] VCOP 0.000 0.236 1.689 0.863 6.493
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.235 2.514 2.993 24.425 0.000 kW
2.514 kWh
0.000 kW
2.514 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.34 V Current/Power -34.00 A (-1.779 kW)
Remain Capacity/Energy 308.9 Ah (15.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 51.5 % State Of Health 100.0 %
Run Time 9h 5m to empty Report Date 2023-03-29 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.