| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 2.800 kW | |||
|---|---|---|---|
| 07/04/2026 20:18 (2229 days) | Production | Consumption | NET Usage |
| Now | 0.225 kW | 3.025 kW | 2.800 kW |
| Today | 32.587 kWh (1.602 kW) | 36.568 kWh (1.798 kW) | 3.981 kWh (0.196 kW) |
| - This Week | 208.539 kWh (30.459 kWh/day) | 238.485 kWh (34.833 kWh/day) | 29.946 kWh (4.374 kWh/day) |
| - This Month | 126.938 kWh (32.995 kWh/day) | 164.345 kWh (42.718 kWh/day) | 37.407 kWh (9.723 kWh/day) |
| - This Year | 3.737 MWh (20.216 kWh/day) | 3.451 MWh (18.670 kWh/day) | -0.286 MWh (-1.545 kWh/day) |
| Yesterday | 33.078 kWh (1.378 kW) | 41.779 kWh (1.741 kW) | 8.701 kWh (0.363 kW) |
| Last 7 Days | 208.539 kWh (29.791 kWh/day) | 242.798 kWh (34.685 kWh/day) | 34.259 kWh (4.894 kWh/day) |
| Last 30 Days (06/04/2026) | 850.771 kWh (28.359 kWh/day) | 826.789 kWh (27.560 kWh/day) | -23.982 kWh (-0.799 kWh/day) |
| Last One Year | 6.723 MWh (18.419 kWh/day) | 7.747 MWh (21.224 kWh/day) | 1.024 MWh (2.805 kWh/day) |
| Lifetime Since PTO | 39.302 MWh (17.626 kW/day) | 42.962 MWh (19.267 kW/day) | 3.659 MWh (1.641 kW/day) |
| Lifetime Since Install | 39.336 MWh | 43.542 MWh | 4.206 MWh |
| Voltage/Current | 248.9 V / 0.9 A | 248.9 V / 12.2 A | 248.9 V / 11.3 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 10/22/2023 23:02 (10.6 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 12.454 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.296 | 0.891 | 0.516 | 5.647 | 0.000 kW 0.867 kWh |
0.000 kW 5.205 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.290 | 0.848 | 0.488 | 5.364 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.295 | 0.880 | 0.514 | 5.559 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.296 | 0.877 | 0.512 | 5.566 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.290 | 0.844 | 0.487 | 5.341 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.295 | 0.865 | 0.501 | 5.487 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.296 | 0.854 | 0.554 | 5.342 | 0.000 kW 0.904 kWh |
0.000 kW 4.521 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 0.876 | 0.560 | 5.823 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.297 | 0.942 | 0.563 | 5.971 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 0.931 | 0.562 | 5.964 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 0.917 | 0.565 | 5.955 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.187 | 0.636 | 0.336 | 3.954 | 0.000 kW 0.682 kWh |
0.000 kW 2.729 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.178 | 0.678 | 0.361 | 4.188 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.182 | 0.707 | 0.384 | 4.365 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.182 | 0.708 | 0.385 | 4.355 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122344****** | IQ7AS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 2.468 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.70 V | Current/Power | -1.50 A (-79 W) |
| Remain Capacity/Energy | 300.6 Ah (15.4 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 50.7 % | State Of Health | 98.9 % |
| Run Time | 8d 8h 24m to empty | Report Date | 2023-10-22 23:57 |
|
|||
| Voltage | 52.71 V | Cell (MIN/MAX) | 3.287 V / 3.301 V (0.014 V) |
|---|---|---|---|
| Current/Power | -0.47 A (-24 W) | Runtime | 8d 20h 44m to empty |
| Remain Capacity/Energy | 100.2 Ah (5.1 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
| State Of Charge | 50.7 % | State Of Health | 98.8 % |
| Temperature | 22.0 °C | Cycle | 123 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-10-22 23:57 |
| Voltage | 52.69 V | Cell (MIN/MAX) | 3.292 V / 3.293 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 72.1 Ah (3.7 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 72.5 % | State Of Health | 99.5 % |
| Temperature | 22.4 °C | Cycle | 67 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-10-22 23:58 |
| Voltage | 52.72 V | Cell (MIN/MAX) | 3.294 V / 3.296 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 71.4 Ah (3.7 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 71.8 % | State Of Health | 99.5 % |
| Temperature | 23.1 °C | Cycle | 70 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-10-22 23:58 |
| Voltage | 52.70 V | Cell (MIN/MAX) | 3.293 V / 3.293 V (0.000 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 71.6 Ah (3.7 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 72.0 % | State Of Health | 99.5 % |
| Temperature | 23.6 °C | Cycle | 72 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-10-22 23:58 |
| Voltage | 52.69 V | Cell (MIN/MAX) | 3.292 V / 3.293 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 70.7 Ah (3.6 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 71.3 % | State Of Health | 99.2 % |
| Temperature | 22.6 °C | Cycle | 70 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-10-22 23:58 |