Date Offset  [+30][+10][+05][+01][-01]

Exporting to grid by 0.823 kW
07/01/2026 08:55 (2226 days) Production Consumption NET Usage
Now 1.353 kW 0.530 kW -0.823 kW
Today 1.683 kWh (0.188 kW) 7.089 kWh (0.793 kW) 5.406 kWh (0.605 kW)
  - This Week 83.284 kWh (24.700 kWh/day) 81.229 kWh (24.090 kWh/day) -2.055 kWh (-0.609 kWh/day)
  - This Month 1.683 kWh (4.518 kWh/day) 7.089 kWh (19.031 kWh/day) 5.406 kWh (14.513 kWh/day)
  - This Year 3.612 MWh (19.912 kWh/day) 3.294 MWh (18.161 kWh/day) -0.318 MWh (-1.751 kWh/day)
Yesterday 26.873 kWh (1.121 kW) 21.329 kWh (0.889 kW) -5.544 kWh (-0.231 kW)
Last 7 Days 170.865 kWh (24.409 kWh/day) 156.271 kWh (22.324 kWh/day) -14.594 kWh (-2.085 kWh/day)
Last 30 Days (06/01/2026) 874.797 kWh (29.160 kWh/day) 719.910 kWh (23.997 kWh/day) -154.887 kWh (-5.163 kWh/day)
Last One Year 6.696 MWh (18.344 kWh/day) 7.718 MWh (21.145 kWh/day) 1.023 MWh (2.802 kWh/day)
Lifetime Since PTO 39.177 MWh (17.597 kW/day) 42.805 MWh (19.226 kW/day) 3.627 MWh (1.629 kW/day)
Lifetime Since Install 39.211 MWh 43.385 MWh 4.174 MWh
Voltage/Current 248.3 V / 5.4 A 248.4 V / 2.1 A 248.3 V / -3.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:15]
Recent Report Data/Time 07/01/2026 08:55 (3.4 hours) Number of Devices 18 set
Current Power 1.389 kW (0.077 kW/panel) Today Energy 1.766 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.104 0.104 0.097 1.924 12.131 0.061 kW
0.058 kWh
0.365 kW
0.350 kWh
02 - 202244****** IQ7+M [5] VCOP 0.076 0.076 0.050 1.791 11.376
03 - 202224****** IQ7+M [5] VCOP 0.029 0.029 0.047 1.835 11.621
04 - 202232****** IQ7+ [5] VCOP 0.031 0.031 0.047 1.861 11.750
05 - 202244****** IQ7+M [5] VCOP 0.021 0.021 0.038 1.655 10.453
06 - 202245****** IQ7+M [5] VCOP 0.104 0.104 0.071 1.859 11.760
front 07 - 202206****** IQ7+ [5] VCOP 0.037 0.037 0.045 1.686 10.711 0.038 kW
0.046 kWh
0.192 kW
0.232 kWh
08 - 202245****** IQ7+M [5] VCOP 0.039 0.039 0.047 1.651 10.625
09 - 202217****** IQ7+ [5] VCOP 0.038 0.038 0.047 1.693 10.769
10 - 202244****** IQ7+M [5] VCOP 0.039 0.039 0.047 1.726 10.928
11 - 202224****** IQ7+M [5] VCOP 0.039 0.039 0.046 1.761 11.114
back 12 - 202211****** IQ7+ [5] VCOP 0.163 0.163 0.249 1.855 11.761 0.166 kW
0.256 kWh
0.665 kW
1.024 kWh
13 - 202223****** IQ7+ [5] VCOP 0.166 0.167 0.253 1.848 11.814
14 - 202216****** IQ7+ [5] VCOP 0.169 0.170 0.259 1.917 12.204
15 - 202245****** IQ7+M [5] VCOP 0.167 0.171 0.263 1.932 12.272
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 2.179 17.192 0.056 kW
0.053 kWh
0.167 kW
0.159 kWh
17 - 122344****** IQ7AS [4] VCOP 0.167 0.167 0.159 1.864 7.259
18 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 3.463
Panel Layout Each Group Production

Charger History
Voltage PV 109.00 V (5.66 A) Voltage Charge 52.94 V Current/Power 11.07 A / 0.586 kW
Int/Ext Temp 40.8 °C / 27.5 °C Flags 00/00/0D Energy Today 0.467 kWh @ 2026-07-01 08:54
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.00 V Current/Power 9.60 A (0.509 kW)
Remain Capacity/Energy 299.1 Ah (15.3 kWh) Full Capacity/Energy 548.1 Ah (28.1 kWh)
State Of Charge 54.6 % State Of Health 91.4 %
Run Time 1d 1h 56m to full Report Date 2026-07-01 08:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.