Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.075 kW
07/09/2025 08:08 (1869 days) Production Consumption NET Usage
Now 0.848 kW 0.773 kW -0.075 kW
Today 0.831 kWh (0.102 kW) 6.519 kWh (0.798 kW) 5.688 kWh (0.696 kW)
  - This Week 75.380 kWh (22.566 kWh/day) 158.185 kWh (47.354 kWh/day) 82.805 kWh (24.788 kWh/day)
  - This Month 205.089 kWh (24.591 kWh/day) 326.911 kWh (39.197 kWh/day) 121.822 kWh (14.607 kWh/day)
  - This Year 3.235 MWh (17.085 kWh/day) 3.454 MWh (18.243 kWh/day) 0.219 MWh (1.158 kWh/day)
Yesterday 25.246 kWh (1.052 kW) 40.320 kWh (1.681 kW) 15.074 kWh (0.628 kW)
Last 7 Days 183.276 kWh (26.183 kWh/day) 289.029 kWh (41.290 kWh/day) 105.753 kWh (15.108 kWh/day)
Last 30 Days 633.297 kWh (21.111 kWh/day) 941.634 kWh (31.389 kWh/day) 308.337 kWh (10.278 kWh/day)
Last One Year 6.301 MWh (17.264 kWh/day) 6.479 MWh (17.750 kWh/day) 0.177 MWh (0.486 kWh/day)
Lifetime Since PTO 32.686 MWh (17.485 kW/day) 35.406 MWh (18.940 kW/day) 2.720 MWh (1.455 kW/day)
Lifetime Since Install 32.720 MWh 35.986 MWh 3.266 MWh
Voltage/Current 247.6 V / 3.4 A 247.6 V / 3.1 A 247.6 V / -0.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/06/2022 23:39 (11.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.632 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.251 1.639 0.409 4.159 0.000 kW
1.589 kWh
0.000 kW
9.532 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.243 1.573 0.392 3.940
03 - 202224****** IQ7+M [5] VCOP 0.000 0.248 1.627 0.400 4.134
04 - 202232****** IQ7+ [5] VCOP 0.000 0.247 1.588 0.394 4.029
05 - 202244****** IQ7+M [5] VCOP 0.000 0.244 1.576 0.381 3.960
06 - 202245****** IQ7+M [5] VCOP 0.000 0.239 1.529 0.393 3.872
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.278 1.627 0.383 3.905 0.000 kW
1.741 kWh
0.000 kW
8.706 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.281 1.755 0.381 4.060
09 - 202217****** IQ7+ [5] VCOP 0.000 0.279 1.755 0.381 4.058
10 - 202244****** IQ7+M [5] VCOP 0.000 0.276 1.793 0.376 4.044
11 - 202224****** IQ7+M [5] VCOP 0.000 0.278 1.776 0.382 4.032
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.174 1.089 0.369 3.547 0.000 kW
1.098 kWh
0.000 kW
4.394 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.172 1.099 0.377 3.591
14 - 202216****** IQ7+ [5] VCOP 0.000 0.174 1.120 0.385 3.629
15 - 202245****** IQ7+M [5] VCOP 0.000 0.171 1.086 0.367 3.523
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.77 V Current/Power -1.56 A (-82 W)
Remain Capacity/Energy 319.8 Ah (16.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 53.3 % State Of Health 100.0 %
Run Time 8d 13h 0m to empty Report Date 2022-10-06 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.