Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.229 kW
09/12/2025 09:00 (1934 days) Production Consumption NET Usage
Now 0.644 kW 0.415 kW -0.229 kW
Today 0.831 kWh (0.092 kW) 4.486 kWh (0.497 kW) 3.655 kWh (0.405 kW)
  - This Week 106.318 kWh (19.777 kWh/day) 72.581 kWh (13.502 kWh/day) -33.737 kWh (-6.276 kWh/day)
  - This Month 243.246 kWh (21.383 kWh/day) 268.306 kWh (23.586 kWh/day) 25.060 kWh (2.203 kWh/day)
  - This Year 4.751 MWh (18.675 kWh/day) 5.439 MWh (21.382 kWh/day) 0.688 MWh (2.706 kWh/day)
Yesterday 26.396 kWh (1.101 kW) 14.540 kWh (0.606 kW) -11.856 kWh (-0.494 kW)
Last 7 Days 143.227 kWh (20.460 kWh/day) 158.213 kWh (22.601 kWh/day) 14.986 kWh (2.141 kWh/day)
Last 30 Days 685.205 kWh (22.841 kWh/day) 773.641 kWh (25.789 kWh/day) 88.436 kWh (2.948 kWh/day)
Last One Year 6.279 MWh (17.202 kWh/day) 7.076 MWh (19.386 kWh/day) 0.797 MWh (2.184 kWh/day)
Lifetime Since PTO 34.201 MWh (17.681 kW/day) 37.391 MWh (19.330 kW/day) 3.190 MWh (1.649 kW/day)
Lifetime Since Install 34.235 MWh 37.971 MWh 3.736 MWh
Voltage/Current 251.8 V / 2.6 A 251.9 V / 1.6 A 251.8 V / -0.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/08/2022 22:35 (9.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 7.230 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.172 0.524 0.106 3.836 0.000 kW
0.508 kWh
0.000 kW
3.049 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.169 0.499 0.096 3.688
03 - 202224****** IQ7+M [5] VCOP 0.000 0.172 0.514 0.104 3.874
04 - 202232****** IQ7+ [5] VCOP 0.000 0.172 0.518 0.102 3.838
05 - 202244****** IQ7+M [5] VCOP 0.000 0.171 0.494 0.095 3.780
06 - 202245****** IQ7+M [5] VCOP 0.000 0.169 0.500 0.097 3.684
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.234 0.523 0.094 3.979 0.000 kW
0.543 kWh
0.000 kW
2.717 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.239 0.540 0.094 4.422
09 - 202217****** IQ7+ [5] VCOP 0.000 0.235 0.571 0.089 4.695
10 - 202244****** IQ7+M [5] VCOP 0.000 0.237 0.558 0.094 4.649
11 - 202224****** IQ7+M [5] VCOP 0.000 0.236 0.526 0.091 4.397
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.072 0.362 0.104 1.755 0.000 kW
0.366 kWh
0.000 kW
1.464 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.073 0.366 0.106 1.964
14 - 202216****** IQ7+ [5] VCOP 0.000 0.074 0.373 0.106 1.981
15 - 202245****** IQ7+M [5] VCOP 0.000 0.072 0.364 0.094 1.898
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.46 V Current/Power -5.92 A (-0.311 kW)
Remain Capacity/Energy 265.5 Ah (13.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 44.2 % State Of Health 100.0 %
Run Time 1d 20h 50m to empty Report Date 2022-12-08 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.