Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.093 kW
01/13/2026 15:44 (2057 days) Production Consumption NET Usage
Now 0.470 kW 0.563 kW 0.093 kW
Today 13.174 kWh (0.836 kW) 8.220 kWh (0.522 kW) -4.954 kWh (-0.314 kW)
  - This Week 37.213 kWh (14.012 kWh/day) 40.783 kWh (15.356 kWh/day) 3.570 kWh (1.344 kWh/day)
  - This Month 113.024 kWh (8.930 kWh/day) 239.517 kWh (18.925 kWh/day) 126.493 kWh (9.994 kWh/day)
  - This Year 0.113 MWh (8.930 kWh/day) 0.240 MWh (18.925 kWh/day) 0.126 MWh (9.994 kWh/day)
Yesterday 14.545 kWh (0.606 kW) 16.751 kWh (0.698 kW) 2.206 kWh (0.092 kW)
Last 7 Days 58.918 kWh (8.417 kWh/day) 155.903 kWh (22.272 kWh/day) 96.985 kWh (13.855 kWh/day)
Last 30 Days 224.926 kWh (7.497 kWh/day) 612.416 kWh (20.413 kWh/day) 387.490 kWh (12.916 kWh/day)
Last One Year 6.097 MWh (16.705 kWh/day) 7.473 MWh (20.475 kWh/day) 1.376 MWh (3.770 kWh/day)
Lifetime Since PTO 35.679 MWh (17.339 kW/day) 39.751 MWh (19.318 kW/day) 4.072 MWh (1.979 kW/day)
Lifetime Since Install 35.713 MWh 40.331 MWh 4.618 MWh
Voltage/Current 249.3 V / 1.9 A 249.1 V / 2.3 A 249.2 V / 0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/05/2023 22:13 (11.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.415 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.068 0.359 1.603 12.294 0.000 kW
0.343 kWh
0.000 kW
2.060 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.064 0.334 1.536 11.825
03 - 202224****** IQ7+M [5] VCOP 0.000 0.068 0.356 1.610 12.293
04 - 202232****** IQ7+ [5] VCOP 0.000 0.068 0.352 1.636 12.373
05 - 202244****** IQ7+M [5] VCOP 0.000 0.061 0.324 1.467 11.453
06 - 202245****** IQ7+M [5] VCOP 0.000 0.064 0.334 1.492 11.626
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.059 0.323 1.466 11.885 0.000 kW
0.327 kWh
0.000 kW
1.633 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.060 0.326 1.568 12.415
09 - 202217****** IQ7+ [5] VCOP 0.000 0.061 0.329 1.562 12.281
10 - 202244****** IQ7+M [5] VCOP 0.000 0.061 0.329 1.566 12.567
11 - 202224****** IQ7+M [5] VCOP 0.000 0.061 0.326 1.583 12.685
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.061 0.317 1.420 9.553 0.000 kW
0.356 kWh
0.000 kW
1.423 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.068 0.348 1.464 9.745
14 - 202216****** IQ7+ [5] VCOP 0.000 0.070 0.379 1.517 10.253
15 - 202245****** IQ7+M [5] VCOP 0.000 0.070 0.379 1.519 10.229
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.649 kWh
0.000 kW
1.299 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.233 1.299 2.264 17.439
Panel Layout Each Group Production

Battery History
Voltage 53.14 V Current/Power -3.33 A (-0.177 kW)
Remain Capacity/Energy 429.3 Ah (22.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 71.6 % State Of Health 100.0 %
Run Time 5d 8h 55m to empty Report Date 2023-04-05 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.