Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.398 kW
01/13/2026 14:28 (2057 days) Production Consumption NET Usage
Now 1.635 kW 0.237 kW -1.398 kW
Today 12.204 kWh (0.842 kW) 7.320 kWh (0.505 kW) -4.884 kWh (-0.337 kW)
  - This Week 36.243 kWh (13.922 kWh/day) 39.883 kWh (15.321 kWh/day) 3.640 kWh (1.398 kWh/day)
  - This Month 112.054 kWh (8.891 kWh/day) 238.617 kWh (18.932 kWh/day) 126.563 kWh (10.042 kWh/day)
  - This Year 0.112 MWh (8.891 kWh/day) 0.239 MWh (18.932 kWh/day) 0.127 MWh (10.042 kWh/day)
Yesterday 14.545 kWh (0.606 kW) 16.751 kWh (0.698 kW) 2.206 kWh (0.092 kW)
Last 7 Days 58.918 kWh (8.417 kWh/day) 155.903 kWh (22.272 kWh/day) 96.985 kWh (13.855 kWh/day)
Last 30 Days 224.926 kWh (7.497 kWh/day) 612.416 kWh (20.413 kWh/day) 387.490 kWh (12.916 kWh/day)
Last One Year 6.097 MWh (16.705 kWh/day) 7.473 MWh (20.475 kWh/day) 1.376 MWh (3.770 kWh/day)
Lifetime Since PTO 35.678 MWh (17.339 kW/day) 39.750 MWh (19.318 kW/day) 4.072 MWh (1.979 kW/day)
Lifetime Since Install 35.712 MWh 40.330 MWh 4.618 MWh
Voltage/Current 251.5 V / 6.5 A 251.5 V / 0.9 A 251.5 V / -5.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/30/2023 23:09 (14.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 33.687 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.194 1.999 8.000 0.000 kW
2.140 kWh
0.000 kW
12.841 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.299 2.128 1.918 7.642
03 - 202224****** IQ7+M [5] VCOP 0.000 0.300 2.194 1.996 7.976
04 - 202232****** IQ7+ [5] VCOP 0.000 0.300 2.193 2.015 7.996
05 - 202244****** IQ7+M [5] VCOP 0.000 0.299 2.054 1.849 7.380
06 - 202245****** IQ7+M [5] VCOP 0.000 0.299 2.079 1.876 7.511
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.301 2.102 1.886 7.519 0.000 kW
2.205 kWh
0.000 kW
11.025 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.302 2.208 2.009 7.946
09 - 202217****** IQ7+ [5] VCOP 0.000 0.301 2.173 1.995 7.916
10 - 202244****** IQ7+M [5] VCOP 0.000 0.301 2.259 2.036 8.040
11 - 202224****** IQ7+M [5] VCOP 0.000 0.302 2.282 2.058 8.110
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.237 1.674 1.585 6.431 0.000 kW
1.732 kWh
0.000 kW
6.928 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.244 1.695 1.624 6.663
14 - 202216****** IQ7+ [5] VCOP 0.000 0.248 1.785 1.690 6.991
15 - 202245****** IQ7+M [5] VCOP 0.000 0.246 1.774 1.689 6.974
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
1.446 kWh
0.000 kW
2.893 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.234 2.893 2.514 22.989
Panel Layout Each Group Production

Battery History
Voltage 53.29 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 430.5 Ah (22.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 71.8 % State Of Health 100.0 %
Run Time 11d 23h 0m to empty Report Date 2023-03-30 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.