Importing from grid by 2.436 kW
07/03/2026 01:49 (2228 days) Production Consumption NET Usage
Now 0.226 kW 2.662 kW 2.436 kW
Today 0.417 kWh (0.226 kW) 3.707 kWh (2.005 kW) 3.290 kWh (1.779 kW)
  - This Week 143.291 kWh (28.228 kWh/day) 163.845 kWh (32.277 kWh/day) 20.554 kWh (4.049 kWh/day)
  - This Month 61.690 kWh (29.704 kWh/day) 89.705 kWh (43.193 kWh/day) 28.015 kWh (13.489 kWh/day)
  - This Year 3.672 MWh (20.055 kWh/day) 3.376 MWh (18.443 kWh/day) -0.295 MWh (-1.612 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 172.198 kWh (24.600 kWh/day) 198.046 kWh (28.292 kWh/day) 25.848 kWh (3.693 kWh/day)
Last 30 Days (06/03/2026) 863.461 kWh (28.782 kWh/day) 789.909 kWh (26.330 kWh/day) -73.552 kWh (-2.452 kWh/day)
Last One Year 6.715 MWh (18.397 kWh/day) 7.745 MWh (21.220 kWh/day) 1.031 MWh (2.824 kWh/day)
Lifetime Since PTO 39.237 MWh (17.610 kW/day) 42.887 MWh (19.249 kW/day) 3.650 MWh (1.638 kW/day)
Lifetime Since Install 39.271 MWh 43.467 MWh 4.196 MWh
Voltage/Current 250.3 V / 0.9 A 250.2 V / 10.6 A 250.3 V / 9.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/11/2023 23:59 (23.9 hours) Number of Devices 18 set
Current Power 0.230 kW (0.013 kW/panel) Today Energy 19.341 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.270 0.970 0.766 8.623 0.000 kW
0.948 kWh
0.000 kW
5.691 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.282 0.930 0.728 8.203
03 - 202224****** IQ7+M [0] ---- 0.000 0.288 0.968 0.759 8.528
04 - 202232****** IQ7+ [0] ---- 0.000 0.291 0.975 0.759 8.601
05 - 202244****** IQ7+M [0] ---- 0.000 0.283 0.910 0.720 8.002
06 - 202245****** IQ7+M [0] ---- 0.000 0.289 0.938 0.745 8.236
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.295 0.918 0.770 8.343 0.000 kW
0.933 kWh
0.000 kW
4.667 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.295 0.939 0.774 8.578
09 - 202217****** IQ7+ [0] ---- 0.000 0.290 0.935 0.770 8.495
10 - 202244****** IQ7+M [0] ---- 0.000 0.295 0.932 0.776 8.577
11 - 202224****** IQ7+M [0] ---- 0.000 0.293 0.943 0.781 8.700
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.245 0.829 0.588 7.088 0.000 kW
0.868 kWh
0.000 kW
3.470 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.255 0.862 0.609 7.222
14 - 202216****** IQ7+ [0] ---- 0.000 0.244 0.888 0.640 7.497
15 - 202245****** IQ7+M [0] ---- 0.000 0.245 0.891 0.641 7.506
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.077 kW
1.838 kWh
0.230 kW
5.514 kWh
17 - 122344****** IQ7AS [0] V--- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.230 0.231 5.514 1.298 16.402
Panel Layout Each Group Production

Battery History
Voltage 52.45 V Current/Power -6.24 A (-0.327 kW)
Remain Capacity/Energy 273.3 Ah (14.0 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 46.1 % State Of Health 98.9 %
Run Time 1d 19h 47m to empty Report Date 2023-09-11 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.