Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.185 kW
01/13/2026 15:44 (2057 days) Production Consumption NET Usage
Now 0.388 kW 0.573 kW 0.185 kW
Today 13.177 kWh (0.836 kW) 8.225 kWh (0.522 kW) -4.952 kWh (-0.314 kW)
  - This Week 37.216 kWh (14.011 kWh/day) 40.788 kWh (15.356 kWh/day) 3.572 kWh (1.345 kWh/day)
  - This Month 113.027 kWh (8.930 kWh/day) 239.522 kWh (18.925 kWh/day) 126.495 kWh (9.994 kWh/day)
  - This Year 0.113 MWh (8.930 kWh/day) 0.240 MWh (18.925 kWh/day) 0.126 MWh (9.994 kWh/day)
Yesterday 14.545 kWh (0.606 kW) 16.751 kWh (0.698 kW) 2.206 kWh (0.092 kW)
Last 7 Days 58.918 kWh (8.417 kWh/day) 155.903 kWh (22.272 kWh/day) 96.985 kWh (13.855 kWh/day)
Last 30 Days 224.926 kWh (7.497 kWh/day) 612.416 kWh (20.413 kWh/day) 387.490 kWh (12.916 kWh/day)
Last One Year 6.097 MWh (16.705 kWh/day) 7.473 MWh (20.475 kWh/day) 1.376 MWh (3.770 kWh/day)
Lifetime Since PTO 35.679 MWh (17.339 kW/day) 39.751 MWh (19.318 kW/day) 4.072 MWh (1.979 kW/day)
Lifetime Since Install 35.713 MWh 40.331 MWh 4.618 MWh
Voltage/Current 249.1 V / 1.6 A 248.9 V / 2.3 A 249.0 V / 0.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/22/2023 22:31 (16.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 24.370 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.446 1.858 12.303 0.000 kW
1.417 kWh
0.000 kW
8.500 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.383 1.779 11.776
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.439 1.844 12.204
04 - 202232****** IQ7+ [5] VCOP 0.000 0.298 1.451 1.851 12.232
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.381 1.727 11.592
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.400 1.746 11.724
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.395 1.794 12.007 0.000 kW
1.448 kWh
0.000 kW
7.238 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.457 1.949 12.783
09 - 202217****** IQ7+ [5] VCOP 0.000 0.299 1.462 1.956 12.733
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.456 1.967 12.902
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.468 1.977 12.982
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.217 1.108 1.285 8.375 0.000 kW
1.171 kWh
0.000 kW
4.683 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.227 1.161 1.333 8.725
14 - 202216****** IQ7+ [5] VCOP 0.000 0.231 1.207 1.399 9.161
15 - 202245****** IQ7+M [5] VCOP 0.000 0.232 1.207 1.394 9.119
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
1.975 kWh
0.000 kW
3.949 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.234 3.949 3.581 24.692
Panel Layout Each Group Production

Battery History
Voltage 52.96 V Current/Power -5.17 A (-0.274 kW)
Remain Capacity/Energy 369.6 Ah (18.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 61.6 % State Of Health 100.0 %
Run Time 2d 23h 29m to empty Report Date 2023-03-22 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.