Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.497 kW
05/15/2026 15:21 (2179 days) Production Consumption NET Usage
Now 1.577 kW 0.080 kW -1.497 kW
Today 17.552 kWh (1.143 kW) 4.945 kWh (0.322 kW) -12.607 kWh (-0.821 kW)
  - This Week 147.080 kWh (26.076 kWh/day) 71.097 kWh (12.605 kWh/day) -75.983 kWh (-13.471 kWh/day)
  - This Month 365.155 kWh (24.942 kWh/day) 188.234 kWh (12.858 kWh/day) -176.921 kWh (-12.085 kWh/day)
  - This Year 2.318 MWh (17.218 kWh/day) 2.248 MWh (16.696 kWh/day) -0.070 MWh (-0.522 kWh/day)
Yesterday 22.227 kWh (0.926 kW) 14.790 kWh (0.616 kW) -7.437 kWh (-0.310 kW)
Last 7 Days 162.014 kWh (23.145 kWh/day) 98.713 kWh (14.102 kWh/day) -63.301 kWh (-9.043 kWh/day)
Last 30 Days (04/15/2026) 689.898 kWh (22.997 kWh/day) 411.682 kWh (13.723 kWh/day) -278.216 kWh (-9.274 kWh/day)
Last One Year 6.338 MWh (17.364 kWh/day) 7.790 MWh (21.343 kWh/day) 1.452 MWh (3.979 kWh/day)
Lifetime Since PTO 37.884 MWh (17.381 kW/day) 41.759 MWh (19.159 kW/day) 3.875 MWh (1.778 kW/day)
Lifetime Since Install 37.918 MWh 42.339 MWh 4.421 MWh
Voltage/Current 249.7 V / 6.3 A 249.6 V / 0.3 A 249.7 V / -6.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/20/2023 23:32 (14.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.063 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.290 1.548 1.088 9.488 0.000 kW
1.475 kWh
0.000 kW
8.851 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.282 1.450 1.035 8.995
03 - 202224****** IQ7+M [5] VCOP 0.000 0.291 1.494 1.077 9.270
04 - 202232****** IQ7+ [5] VCOP 0.000 0.290 1.517 1.085 9.388
05 - 202244****** IQ7+M [5] VCOP 0.000 0.278 1.356 1.024 8.601
06 - 202245****** IQ7+M [5] VCOP 0.000 0.284 1.486 1.054 9.209
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 1.379 1.038 8.702 0.000 kW
1.379 kWh
0.000 kW
6.893 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.290 1.357 1.029 8.687
09 - 202217****** IQ7+ [5] VCOP 0.000 0.286 1.362 1.035 8.704
10 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.388 1.042 8.740
11 - 202224****** IQ7+M [5] VCOP 0.000 0.292 1.407 1.054 8.835
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.247 1.491 0.909 8.654 0.000 kW
1.545 kWh
0.000 kW
6.182 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.253 1.530 0.938 8.879
14 - 202216****** IQ7+ [5] VCOP 0.000 0.255 1.575 0.986 9.220
15 - 202245****** IQ7+M [5] VCOP 0.000 0.256 1.585 0.987 9.267
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.569 kWh
0.000 kW
1.137 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.230 1.137 1.130 8.101
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -5.89 A (-0.313 kW)
Remain Capacity/Energy 495.1 Ah (25.4 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 83.5 % State Of Health 98.9 %
Run Time 3d 12h 3m to empty Report Date 2023-07-20 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.