| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.490 kW | |||
|---|---|---|---|
| 07/03/2026 02:22 (2228 days) | Production | Consumption | NET Usage |
| Now | 0.226 kW | 0.716 kW | 0.490 kW |
| Today | 0.542 kWh (0.225 kW) | 4.595 kWh (1.910 kW) | 4.053 kWh (1.684 kW) |
| - This Week | 143.416 kWh (28.124 kWh/day) | 164.733 kWh (32.304 kWh/day) | 21.317 kWh (4.180 kWh/day) |
| - This Month | 61.815 kWh (29.435 kWh/day) | 90.593 kWh (43.139 kWh/day) | 28.778 kWh (13.704 kWh/day) |
| - This Year | 3.672 MWh (20.053 kWh/day) | 3.377 MWh (18.446 kWh/day) | -0.294 MWh (-1.607 kWh/day) |
| Yesterday | 35.642 kWh (1.485 kW) | 43.847 kWh (1.826 kW) | 8.205 kWh (0.342 kW) |
| Last 7 Days | 172.323 kWh (24.618 kWh/day) | 198.886 kWh (28.412 kWh/day) | 26.563 kWh (3.795 kWh/day) |
| Last 30 Days (06/03/2026) | 863.400 kWh (28.780 kWh/day) | 790.591 kWh (26.353 kWh/day) | -72.809 kWh (-2.427 kWh/day) |
| Last One Year | 6.715 MWh (18.397 kWh/day) | 7.746 MWh (21.222 kWh/day) | 1.031 MWh (2.825 kWh/day) |
| Lifetime Since PTO | 39.237 MWh (17.610 kW/day) | 42.888 MWh (19.249 kW/day) | 3.651 MWh (1.639 kW/day) |
| Lifetime Since Install | 39.271 MWh | 43.468 MWh | 4.197 MWh |
| Voltage/Current | 251.7 V / 0.9 A | 251.7 V / 2.8 A | 251.7 V / 1.9 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 09/03/2023 23:43 (12.7 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 27.255 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.266 | 1.846 | 1.971 | 11.255 | 0.000 kW 1.774 kWh |
0.000 kW 10.646 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.251 | 1.747 | 1.878 | 10.720 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.259 | 1.808 | 1.952 | 11.164 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.263 | 1.831 | 1.978 | 11.330 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.253 | 1.680 | 1.803 | 10.376 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.259 | 1.734 | 1.862 | 10.738 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.286 | 1.782 | 1.919 | 10.896 | 0.000 kW 1.827 kWh |
0.000 kW 9.133 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.285 | 1.828 | 1.963 | 11.049 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.282 | 1.799 | 1.945 | 10.922 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.282 | 1.842 | 1.977 | 11.093 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.288 | 1.882 | 2.018 | 11.311 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.206 | 1.495 | 1.606 | 9.355 | 0.000 kW 1.528 kWh |
0.000 kW 6.111 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.210 | 1.509 | 1.617 | 9.479 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.211 | 1.556 | 1.681 | 9.829 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.211 | 1.551 | 1.682 | 9.851 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.455 kWh |
0.000 kW 1.365 kWh |
| 17 - 122344****** | IQ7AS | [0] V--- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.230 | 1.365 | 1.361 | 14.121 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.55 V | Current/Power | -4.58 A (-0.241 kW) |
| Remain Capacity/Energy | 185.8 Ah (9.5 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 31.3 % | State Of Health | 98.9 % |
| Run Time | 1d 16h 33m to empty | Report Date | 2023-09-03 23:59 |
|
|||
| Voltage | 52.53 V | Cell (MIN/MAX) | 3.278 V / 3.287 V (0.009 V) |
|---|---|---|---|
| Current/Power | -1.39 A (-72 W) | Runtime | 1d 20h 40m to empty |
| Remain Capacity/Energy | 61.9 Ah (3.2 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
| State Of Charge | 31.3 % | State Of Health | 98.8 % |
| Temperature | 25.0 °C | Cycle | 117 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-09-03 23:59 |
| Voltage | 52.55 V | Cell (MIN/MAX) | 3.283 V / 3.285 V (0.002 V) |
|---|---|---|---|
| Current/Power | -0.88 A (-46 W) | Runtime | 2d 6h 10m to empty |
| Remain Capacity/Energy | 47.8 Ah (2.4 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 48.1 % | State Of Health | 99.5 % |
| Temperature | 25.0 °C | Cycle | 63 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-09-03 23:59 |
| Voltage | 52.57 V | Cell (MIN/MAX) | 3.285 V / 3.287 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.09 A (-57 W) | Runtime | 1d 18h 19m to empty |
| Remain Capacity/Energy | 46.3 Ah (2.4 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 46.5 % | State Of Health | 99.5 % |
| Temperature | 26.0 °C | Cycle | 66 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-09-03 23:59 |
| Voltage | 52.54 V | Cell (MIN/MAX) | 3.283 V / 3.285 V (0.002 V) |
|---|---|---|---|
| Current/Power | -0.98 A (-51 W) | Runtime | 1d 23h 14m to empty |
| Remain Capacity/Energy | 46.5 Ah (2.4 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 46.7 % | State Of Health | 99.5 % |
| Temperature | 26.3 °C | Cycle | 68 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-09-03 23:59 |
| Voltage | 52.54 V | Cell (MIN/MAX) | 3.283 V / 3.285 V (0.002 V) |
|---|---|---|---|
| Current/Power | -0.90 A (-47 W) | Runtime | 2d 3h 25m to empty |
| Remain Capacity/Energy | 46.0 Ah (2.4 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 46.4 % | State Of Health | 99.2 % |
| Temperature | 25.0 °C | Cycle | 66 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-09-03 23:59 |