Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.490 kW
07/03/2026 02:22 (2228 days) Production Consumption NET Usage
Now 0.226 kW 0.716 kW 0.490 kW
Today 0.542 kWh (0.225 kW) 4.595 kWh (1.910 kW) 4.053 kWh (1.684 kW)
  - This Week 143.416 kWh (28.124 kWh/day) 164.733 kWh (32.304 kWh/day) 21.317 kWh (4.180 kWh/day)
  - This Month 61.815 kWh (29.435 kWh/day) 90.593 kWh (43.139 kWh/day) 28.778 kWh (13.704 kWh/day)
  - This Year 3.672 MWh (20.053 kWh/day) 3.377 MWh (18.446 kWh/day) -0.294 MWh (-1.607 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 172.323 kWh (24.618 kWh/day) 198.886 kWh (28.412 kWh/day) 26.563 kWh (3.795 kWh/day)
Last 30 Days (06/03/2026) 863.400 kWh (28.780 kWh/day) 790.591 kWh (26.353 kWh/day) -72.809 kWh (-2.427 kWh/day)
Last One Year 6.715 MWh (18.397 kWh/day) 7.746 MWh (21.222 kWh/day) 1.031 MWh (2.825 kWh/day)
Lifetime Since PTO 39.237 MWh (17.610 kW/day) 42.888 MWh (19.249 kW/day) 3.651 MWh (1.639 kW/day)
Lifetime Since Install 39.271 MWh 43.468 MWh 4.197 MWh
Voltage/Current 251.7 V / 0.9 A 251.7 V / 2.8 A 251.7 V / 1.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/31/2023 23:49 (19.4 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 33.889 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.287 2.127 1.555 7.411 0.000 kW
2.065 kWh
0.000 kW
12.390 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.273 2.028 1.479 7.053
03 - 202224****** IQ7+M [0] ---- 0.000 0.282 2.117 1.531 7.329
04 - 202232****** IQ7+ [0] ---- 0.000 0.286 2.160 1.542 7.398
05 - 202244****** IQ7+M [0] ---- 0.000 0.274 1.944 1.489 6.905
06 - 202245****** IQ7+M [0] ---- 0.000 0.281 2.014 1.526 7.158
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 2.090 1.583 7.089 0.000 kW
2.119 kWh
0.000 kW
10.593 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 2.110 1.557 7.080
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 2.070 1.552 7.040
10 - 202244****** IQ7+M [0] ---- 0.000 0.292 2.130 1.571 7.148
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 2.193 1.593 7.254
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.229 1.707 1.156 6.246 0.000 kW
1.748 kWh
0.000 kW
6.993 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.233 1.712 1.170 6.394
14 - 202216****** IQ7+ [0] ---- 0.000 0.236 1.787 1.207 6.629
15 - 202245****** IQ7+M [0] ---- 0.000 0.236 1.787 1.210 6.653
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
1.305 kWh
0.000 kW
3.914 kWh
17 - 122344****** IQ7AS [0] V--- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.230 3.914 2.315 10.002
Panel Layout Each Group Production

Battery History
Voltage 53.20 V Current/Power -6.09 A (-0.324 kW)
Remain Capacity/Energy 528.5 Ah (27.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 89.1 % State Of Health 98.9 %
Run Time 3d 14h 46m to empty Report Date 2023-08-31 23:58