Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.331 kW
03/09/2026 13:40 (2112 days) Production Consumption NET Usage
Now 3.745 kW 0.414 kW -3.331 kW
Today 13.029 kWh (0.953 kW) 6.743 kWh (0.493 kW) -6.286 kWh (-0.460 kW)
  - This Week 23.755 kWh (15.131 kWh/day) 19.213 kWh (12.238 kWh/day) -4.542 kWh (-2.893 kWh/day)
  - This Month 117.463 kWh (13.707 kWh/day) 125.512 kWh (14.646 kWh/day) 8.049 kWh (0.939 kWh/day)
  - This Year 0.751 MWh (11.120 kWh/day) 1.225 MWh (18.134 kWh/day) 0.474 MWh (7.014 kWh/day)
Yesterday 10.726 kWh (0.447 kW) 12.470 kWh (0.520 kW) 1.744 kWh (0.073 kW)
Last 7 Days 80.716 kWh (11.531 kWh/day) 107.074 kWh (15.296 kWh/day) 26.358 kWh (3.765 kWh/day)
Last 30 Days 391.239 kWh (13.041 kWh/day) 498.996 kWh (16.633 kWh/day) 107.757 kWh (3.592 kWh/day)
Last One Year 6.054 MWh (16.585 kWh/day) 7.791 MWh (21.344 kWh/day) 1.737 MWh (4.759 kWh/day)
Lifetime Since PTO 36.317 MWh (17.191 kW/day) 40.736 MWh (19.283 kW/day) 4.419 MWh (2.092 kW/day)
Lifetime Since Install 36.351 MWh 41.316 MWh 4.965 MWh
Voltage/Current 251.9 V / 14.9 A 251.8 V / 1.6 A 251.8 V / -13.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/22/2025 23:48 (9.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.456 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.207 0.381 0.306 5.066 0.000 kW
0.373 kWh
0.000 kW
2.236 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.201 0.364 0.290 4.843
03 - 202224****** IQ7+M [5] VCOP 0.000 0.207 0.378 0.305 5.050
04 - 202232****** IQ7+ [5] VCOP 0.000 0.207 0.380 0.304 5.067
05 - 202244****** IQ7+M [5] VCOP 0.000 0.200 0.362 0.284 4.863
06 - 202245****** IQ7+M [5] VCOP 0.000 0.205 0.371 0.298 4.950
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.258 0.429 0.300 5.278 0.000 kW
0.432 kWh
0.000 kW
2.160 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.263 0.421 0.302 5.681
09 - 202217****** IQ7+ [5] VCOP 0.000 0.264 0.430 0.303 5.899
10 - 202244****** IQ7+M [5] VCOP 0.000 0.255 0.435 0.304 5.900
11 - 202224****** IQ7+M [5] VCOP 0.000 0.263 0.446 0.303 5.780
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.109 0.241 0.251 2.655 0.000 kW
0.265 kWh
0.000 kW
1.061 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.104 0.255 0.266 2.991
14 - 202216****** IQ7+ [5] VCOP 0.000 0.124 0.285 0.283 3.124
15 - 202245****** IQ7+M [5] VCOP 0.000 0.131 0.280 0.283 3.088
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 14.828
Panel Layout Each Group Production

Charger History
Voltage PV 0.82 V Voltage Charge 52.34 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 27.8 °C / 24.6 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-11-22 23:56
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.56 V Current/Power -1.80 A (-94 W)
Remain Capacity/Energy 211.9 Ah (10.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 35.7 % State Of Health 98.9 %
Run Time 4d 21h 45m to empty Report Date 2025-11-22 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.