Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.567 kW
05/15/2026 17:53 (2179 days) Production Consumption NET Usage
Now 0.699 kW 0.132 kW -0.567 kW
Today 20.474 kWh (1.144 kW) 6.055 kWh (0.338 kW) -14.419 kWh (-0.806 kW)
  - This Week 150.002 kWh (26.105 kWh/day) 72.207 kWh (12.566 kWh/day) -77.795 kWh (-13.539 kWh/day)
  - This Month 368.077 kWh (24.962 kWh/day) 189.344 kWh (12.841 kWh/day) -178.733 kWh (-12.121 kWh/day)
  - This Year 2.321 MWh (17.226 kWh/day) 2.249 MWh (16.691 kWh/day) -0.072 MWh (-0.535 kWh/day)
Yesterday 22.227 kWh (0.926 kW) 14.790 kWh (0.616 kW) -7.437 kWh (-0.310 kW)
Last 7 Days 160.474 kWh (22.925 kWh/day) 93.731 kWh (13.390 kWh/day) -66.743 kWh (-9.535 kWh/day)
Last 30 Days (04/15/2026) 686.823 kWh (22.894 kWh/day) 407.968 kWh (13.599 kWh/day) -278.855 kWh (-9.295 kWh/day)
Last One Year 6.338 MWh (17.364 kWh/day) 7.790 MWh (21.343 kWh/day) 1.453 MWh (3.980 kWh/day)
Lifetime Since PTO 37.887 MWh (17.381 kW/day) 41.760 MWh (19.158 kW/day) 3.873 MWh (1.777 kW/day)
Lifetime Since Install 37.921 MWh 42.340 MWh 4.419 MWh
Voltage/Current 251.3 V / 2.8 A 251.5 V / 0.5 A 251.4 V / -2.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/07/2023 23:29 (14.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.985 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.177 1.130 1.539 12.053 0.000 kW
1.074 kWh
0.000 kW
6.446 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.168 1.058 1.453 11.269
03 - 202224****** IQ7+M [5] VCOP 0.000 0.173 1.091 1.500 11.482
04 - 202232****** IQ7+ [5] VCOP 0.000 0.174 1.099 1.514 11.734
05 - 202244****** IQ7+M [5] VCOP 0.000 0.165 0.982 1.404 10.246
06 - 202245****** IQ7+M [5] VCOP 0.000 0.171 1.087 1.490 11.622
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.149 0.982 1.387 10.698 0.000 kW
0.993 kWh
0.000 kW
4.966 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.152 0.991 1.397 10.586
09 - 202217****** IQ7+ [5] VCOP 0.000 0.151 0.994 1.396 10.649
10 - 202244****** IQ7+M [5] VCOP 0.000 0.151 0.996 1.390 10.709
11 - 202224****** IQ7+M [5] VCOP 0.000 0.152 1.003 1.408 10.869
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.179 1.094 1.409 11.956 0.000 kW
1.143 kWh
0.000 kW
4.573 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.183 1.135 1.455 12.105
14 - 202216****** IQ7+ [5] VCOP 0.000 0.187 1.172 1.478 12.500
15 - 202245****** IQ7+M [5] VCOP 0.000 0.186 1.172 1.477 12.473
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 1.586 11.527
Panel Layout Each Group Production

Battery History
Voltage 52.77 V Current/Power -1.86 A (-98 W)
Remain Capacity/Energy 317.7 Ah (16.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 53.0 % State Of Health 100.0 %
Run Time 7d 2h 49m to empty Report Date 2023-06-07 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.