Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.581 kW
07/03/2026 02:50 (2228 days) Production Consumption NET Usage
Now 0.225 kW 2.806 kW 2.581 kW
Today 0.645 kWh (0.225 kW) 5.242 kWh (1.832 kW) 4.597 kWh (1.607 kW)
  - This Week 143.519 kWh (28.040 kWh/day) 165.380 kWh (32.311 kWh/day) 21.861 kWh (4.271 kWh/day)
  - This Month 61.918 kWh (29.220 kWh/day) 91.240 kWh (43.058 kWh/day) 29.322 kWh (13.838 kWh/day)
  - This Year 3.672 MWh (20.051 kWh/day) 3.378 MWh (18.447 kWh/day) -0.294 MWh (-1.604 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 172.426 kWh (24.632 kWh/day) 199.534 kWh (28.505 kWh/day) 27.108 kWh (3.873 kWh/day)
Last 30 Days (06/03/2026) 863.359 kWh (28.779 kWh/day) 791.123 kWh (26.371 kWh/day) -72.236 kWh (-2.408 kWh/day)
Last One Year 6.715 MWh (18.397 kWh/day) 7.746 MWh (21.223 kWh/day) 1.031 MWh (2.826 kWh/day)
Lifetime Since PTO 39.237 MWh (17.610 kW/day) 42.889 MWh (19.249 kW/day) 3.651 MWh (1.639 kW/day)
Lifetime Since Install 39.271 MWh 43.469 MWh 4.197 MWh
Voltage/Current 250.3 V / 0.9 A 250.4 V / 11.2 A 250.4 V / 10.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/10/2023 23:41 (14.2 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.988 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.279 1.630 0.703 10.265 0.000 kW
1.575 kWh
0.000 kW
9.448 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.281 1.548 0.677 9.683
03 - 202224****** IQ7+M [0] ---- 0.000 0.273 1.585 0.701 9.938
04 - 202232****** IQ7+ [0] ---- 0.000 0.292 1.596 0.696 10.085
05 - 202244****** IQ7+M [0] ---- 0.000 0.264 1.505 0.650 9.083
06 - 202245****** IQ7+M [0] ---- 0.000 0.272 1.583 0.680 9.939
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.279 1.546 0.631 9.281 0.000 kW
1.528 kWh
0.000 kW
7.639 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.286 1.460 0.627 9.117
09 - 202217****** IQ7+ [0] ---- 0.000 0.277 1.505 0.636 9.215
10 - 202244****** IQ7+M [0] ---- 0.000 0.281 1.553 0.639 9.313
11 - 202224****** IQ7+M [0] ---- 0.000 0.281 1.575 0.627 9.462
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.254 1.409 0.665 9.523 0.000 kW
1.446 kWh
0.000 kW
5.784 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.258 1.402 0.698 9.677
14 - 202216****** IQ7+ [0] ---- 0.000 0.259 1.487 0.731 10.047
15 - 202245****** IQ7+M [0] ---- 0.000 0.258 1.486 0.743 10.097
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.373 kWh
0.000 kW
1.118 kWh
17 - 122344****** IQ7AS [0] V--- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.230 1.118 1.645 9.109
Panel Layout Each Group Production

Battery History
Voltage 53.30 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 384.9 Ah (19.7 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 64.9 % State Of Health 98.9 %
Run Time 10d 16h 36m to empty Report Date 2023-07-10 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.