Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.633 kW
03/11/2026 12:25 (2114 days) Production Consumption NET Usage
Now 1.828 kW 0.195 kW -1.633 kW
Today 7.016 kWh (0.564 kW) 5.442 kWh (0.437 kW) -1.574 kWh (-0.126 kW)
  - This Week 66.938 kWh (19.025 kWh/day) 47.772 kWh (13.578 kWh/day) -19.166 kWh (-5.447 kWh/day)
  - This Month 160.646 kWh (15.273 kWh/day) 154.071 kWh (14.648 kWh/day) -6.575 kWh (-0.625 kWh/day)
  - This Year 0.795 MWh (11.430 kWh/day) 1.254 MWh (18.037 kWh/day) 0.459 MWh (6.607 kWh/day)
Yesterday 23.741 kWh (0.990 kW) 14.656 kWh (0.611 kW) -9.085 kWh (-0.379 kW)
Last 7 Days 92.430 kWh (13.204 kWh/day) 105.156 kWh (15.022 kWh/day) 12.726 kWh (1.818 kWh/day)
Last 30 Days (02/09/2026) 396.457 kWh (13.215 kWh/day) 500.316 kWh (16.677 kWh/day) 103.859 kWh (3.462 kWh/day)
Last One Year 6.056 MWh (16.591 kWh/day) 7.806 MWh (21.386 kWh/day) 1.750 MWh (4.795 kWh/day)
Lifetime Since PTO 36.360 MWh (17.196 kW/day) 40.765 MWh (19.278 kW/day) 4.404 MWh (2.083 kW/day)
Lifetime Since Install 36.394 MWh 41.345 MWh 4.950 MWh
Voltage/Current 249.3 V / 7.3 A 249.2 V / 0.8 A 249.3 V / -6.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/16/2023 23:59 (12.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.537 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.745 2.046 5.935 0.000 kW
1.691 kWh
0.000 kW
10.146 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.651 1.958 5.642
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.713 2.031 5.877
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.717 2.036 5.843
05 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.646 1.961 5.495
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.673 1.980 5.613
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 1.888 2.018 5.657 0.000 kW
1.892 kWh
0.000 kW
9.460 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.300 1.892 2.163 5.940
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 1.874 2.140 5.978
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.896 2.169 6.010
11 - 202224****** IQ7+M [5] VCOP 0.000 0.299 1.910 2.184 5.959
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.201 1.019 1.228 4.349 0.000 kW
1.088 kWh
0.000 kW
4.351 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.207 1.072 1.288 4.575
14 - 202216****** IQ7+ [5] VCOP 0.000 0.213 1.134 1.359 4.966
15 - 202245****** IQ7+M [5] VCOP 0.000 0.210 1.126 1.349 4.935
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
1.290 kWh
0.000 kW
2.580 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.235 2.580 3.310 10.911
Panel Layout Each Group Production

Battery History
Voltage 55.70 V Current/Power 1.80 A (0.100 kW)
Remain Capacity/Energy 600.0 Ah (30.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 100.0 % State Of Health 100.0 %
Run Time - to full Report Date 2023-03-16 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.