Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.216 kW
07/10/2025 06:06 (1870 days) Production Consumption NET Usage
Now 0.021 kW 0.237 kW 0.216 kW
Today 0.001 kWh (0.000 kW) 4.627 kWh (0.754 kW) 4.626 kWh (0.754 kW)
  - This Week 99.596 kWh (23.404 kWh/day) 196.704 kWh (46.223 kWh/day) 97.108 kWh (22.819 kWh/day)
  - This Month 229.305 kWh (24.776 kWh/day) 365.430 kWh (39.484 kWh/day) 136.125 kWh (14.708 kWh/day)
  - This Year 3.259 MWh (17.130 kWh/day) 3.493 MWh (18.358 kWh/day) 0.234 MWh (1.228 kWh/day)
Yesterday 25.046 kWh (1.044 kW) 40.411 kWh (1.684 kW) 15.365 kWh (0.640 kW)
Last 7 Days 187.533 kWh (26.791 kWh/day) 299.677 kWh (42.813 kWh/day) 112.144 kWh (16.021 kWh/day)
Last 30 Days 652.855 kWh (21.763 kWh/day) 970.553 kWh (32.353 kWh/day) 317.698 kWh (10.590 kWh/day)
Last One Year 6.296 MWh (17.249 kWh/day) 6.482 MWh (17.760 kWh/day) 0.186 MWh (0.511 kWh/day)
Lifetime Since PTO 32.710 MWh (17.490 kW/day) 35.445 MWh (18.952 kW/day) 2.735 MWh (1.462 kW/day)
Lifetime Since Install 32.744 MWh 36.025 MWh 3.281 MWh
Voltage/Current 250.3 V / 0.1 A 250.2 V / 0.9 A 250.2 V / 0.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/08/2022 23:01 (14.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 33.113 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.294 2.404 1.498 12.266 0.000 kW
2.278 kWh
0.000 kW
13.668 kWh
02 - 202244****** IQ7+M [5] VC-- 0.000 0.286 2.252 1.393 11.569
03 - 202224****** IQ7+M [5] VC-- 0.000 0.292 2.306 1.443 11.888
04 - 202232****** IQ7+ [5] VC-- 0.000 0.293 2.270 1.430 11.797
05 - 202244****** IQ7+M [5] VC-- 0.000 0.288 2.148 1.307 11.027
06 - 202245****** IQ7+M [5] VC-- 0.000 0.283 2.289 1.424 11.656
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.292 2.171 1.283 11.061 0.000 kW
2.149 kWh
0.000 kW
10.746 kWh
08 - 202245****** IQ7+M [5] VC-- 0.000 0.292 2.082 1.273 10.783
09 - 202217****** IQ7+ [5] VC-- 0.000 0.290 2.094 1.284 10.801
10 - 202244****** IQ7+M [5] VC-- 0.000 0.291 2.186 1.291 11.037
11 - 202224****** IQ7+M [5] VC-- 0.000 0.291 2.213 1.302 11.186
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.277 2.211 1.710 12.358 0.000 kW
2.175 kWh
0.000 kW
8.699 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.276 2.107 1.710 12.044
14 - 202216****** IQ7+ [5] VCOP 0.000 0.276 2.211 1.731 12.480
15 - 202245****** IQ7+M [5] VCOP 0.000 0.270 2.170 1.714 12.291
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.17 V Current/Power -4.31 A (-0.229 kW)
Remain Capacity/Energy 504.9 Ah (25.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 84.2 % State Of Health 100.0 %
Run Time 4d 21h 8m to empty Report Date 2022-06-08 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.15 V Cell (MIN/MAX) 3.317 V / 3.325 V (0.008 V)
Current/Power -1.21 A (-64 W) Runtime 5d 19h 5m to empty
Remain Capacity/Energy 168.3 Ah (8.6 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 84.2 % State Of Health 100.0 %
Temperature 23.0 °C Cycle 66
MOSFET CFET = ON, DFET = ON Reported 2022-06-08 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.317 V 3.317 V 3.318 V 3.318 V 3.319 V 3.319 V 3.320 V 3.321 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.322 V 3.322 V 3.323 V 3.323 V 3.325 V 3.324 V 3.325 V 3.325 V
pack voltage and current cell voltages
pack temperature
Voltage 53.18 V Cell (MIN/MAX) 3.323 V / 3.324 V (0.001 V)
Current/Power -0.71 A (-37 W) Runtime 5d 14h 8m to empty
Remain Capacity/Energy 95.2 Ah (4.9 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 95.2 % State Of Health 100.0 %
Temperature 22.4 °C Cycle 19
MOSFET CFET = ON, DFET = ON Reported 2022-06-08 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.324 V 3.323 V
pack voltage and current cell voltages
pack temperature
Voltage 53.21 V Cell (MIN/MAX) 3.325 V / 3.326 V (0.001 V)
Current/Power -0.79 A (-42 W) Runtime 4d 23h 40m to empty
Remain Capacity/Energy 94.7 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 94.7 % State Of Health 100.0 %
Temperature 23.5 °C Cycle 19
MOSFET CFET = ON, DFET = ON Reported 2022-06-08 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.325 V 3.326 V 3.326 V 3.325 V 3.326 V 3.325 V 3.326 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V
pack voltage and current cell voltages
pack temperature
Voltage 53.16 V Cell (MIN/MAX) 3.322 V / 3.323 V (0.001 V)
Current/Power -0.79 A (-42 W) Runtime 4d 23h 17m to empty
Remain Capacity/Energy 94.5 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 94.5 % State Of Health 100.0 %
Temperature 23.6 °C Cycle 19
MOSFET CFET = ON, DFET = ON Reported 2022-06-08 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.322 V 3.322 V 3.323 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V
pack voltage and current cell voltages
pack temperature
Voltage 53.17 V Cell (MIN/MAX) 3.322 V / 3.324 V (0.002 V)
Current/Power -0.76 A (-40 W) Runtime 5d 5h 11m to empty
Remain Capacity/Energy 94.6 Ah (4.8 kWh) Full Capacity/Energy 99.7 Ah (5.1 kWh)
State Of Charge 94.9 % State Of Health 99.7 %
Temperature 22.4 °C Cycle 19
MOSFET CFET = ON, DFET = ON Reported 2022-06-08 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.322 V 3.324 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.322 V 3.323 V
pack voltage and current cell voltages
pack temperature