Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.748 kW
09/12/2025 17:31 (1934 days) Production Consumption NET Usage
Now 1.444 kW 0.696 kW -0.748 kW
Today 20.461 kWh (1.166 kW) 8.086 kWh (0.461 kW) -12.375 kWh (-0.705 kW)
  - This Week 125.948 kWh (21.978 kWh/day) 76.181 kWh (13.294 kWh/day) -49.767 kWh (-8.684 kWh/day)
  - This Month 262.876 kWh (22.410 kWh/day) 271.906 kWh (23.180 kWh/day) 9.030 kWh (0.770 kWh/day)
  - This Year 4.770 MWh (18.727 kWh/day) 5.443 MWh (21.366 kWh/day) 0.672 MWh (2.640 kWh/day)
Yesterday 26.396 kWh (1.101 kW) 14.540 kWh (0.606 kW) -11.856 kWh (-0.494 kW)
Last 7 Days 143.227 kWh (20.460 kWh/day) 158.213 kWh (22.601 kWh/day) 14.986 kWh (2.141 kWh/day)
Last 30 Days 685.205 kWh (22.841 kWh/day) 773.641 kWh (25.789 kWh/day) 88.436 kWh (2.948 kWh/day)
Last One Year 6.279 MWh (17.202 kWh/day) 7.076 MWh (19.386 kWh/day) 0.797 MWh (2.184 kWh/day)
Lifetime Since PTO 34.221 MWh (17.688 kW/day) 37.395 MWh (19.328 kW/day) 3.174 MWh (1.640 kW/day)
Lifetime Since Install 34.255 MWh 37.975 MWh 3.720 MWh
Voltage/Current 249.3 V / 5.8 A 249.1 V / 2.8 A 249.2 V / -3.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/28/2022 23:14 (14.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.396 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.244 0.651 9.327 0.000 kW
2.112 kWh
0.000 kW
12.674 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 2.094 0.616 8.826
03 - 202224****** IQ7+M [5] VCOP 0.000 0.299 2.133 0.653 9.060
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.110 0.633 8.957
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.943 0.625 8.277
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.149 0.623 8.890
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 1.988 0.574 8.298 0.000 kW
1.960 kWh
0.000 kW
9.800 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.893 0.573 8.118
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.903 0.577 8.178
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 2.006 0.596 8.390
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 2.010 0.593 8.413
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.292 2.264 0.616 9.498 0.000 kW
2.230 kWh
0.000 kW
8.922 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.291 2.161 0.613 9.258
14 - 202216****** IQ7+ [5] VCOP 0.000 0.293 2.266 0.631 9.553
15 - 202245****** IQ7+M [5] VCOP 0.000 0.289 2.231 0.623 9.402
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.31 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 382.5 Ah (19.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 63.8 % State Of Health 100.0 %
Run Time 10d 15h 0m to empty Report Date 2022-06-28 23:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.