Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.897 kW
01/13/2026 22:53 (2057 days) Production Consumption NET Usage
Now 0.000 kW -1.897 kW -1.897 kW
Today 13.286 kWh (0.580 kW) 9.196 kWh (0.402 kW) -4.090 kWh (-0.179 kW)
  - This Week 37.325 kWh (12.637 kWh/day) 41.759 kWh (14.138 kWh/day) 4.434 kWh (1.501 kWh/day)
  - This Month 113.136 kWh (8.734 kWh/day) 240.493 kWh (18.565 kWh/day) 127.357 kWh (9.831 kWh/day)
  - This Year 0.113 MWh (8.734 kWh/day) 0.240 MWh (18.565 kWh/day) 0.127 MWh (9.831 kWh/day)
Yesterday 14.545 kWh (0.606 kW) 16.751 kWh (0.698 kW) 2.206 kWh (0.092 kW)
Last 7 Days 58.918 kWh (8.417 kWh/day) 155.903 kWh (22.272 kWh/day) 96.985 kWh (13.855 kWh/day)
Last 30 Days 224.926 kWh (7.497 kWh/day) 612.416 kWh (20.413 kWh/day) 387.490 kWh (12.916 kWh/day)
Last One Year 6.097 MWh (16.705 kWh/day) 7.473 MWh (20.475 kWh/day) 1.376 MWh (3.770 kWh/day)
Lifetime Since PTO 35.679 MWh (17.337 kW/day) 39.752 MWh (19.316 kW/day) 4.073 MWh (1.979 kW/day)
Lifetime Since Install 35.713 MWh 40.332 MWh 4.619 MWh
Voltage/Current 252.0 V / 0.0 A 252.0 V / -7.5 A 252.0 V / -7.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/19/2022 22:20 (10.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.443 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.127 1.258 7.604 0.000 kW
1.086 kWh
0.000 kW
6.513 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.056 1.209 7.204
03 - 202224****** IQ7+M [0] ---- 0.000 0.291 1.119 1.260 7.514
04 - 202232****** IQ7+ [0] ---- 0.000 0.294 1.069 1.209 7.256
05 - 202244****** IQ7+M [0] ---- 0.000 0.294 1.098 1.233 7.404
06 - 202245****** IQ7+M [0] ---- 0.000 0.290 1.044 1.218 7.269
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 0.943 1.511 8.165 0.000 kW
1.091 kWh
0.000 kW
5.456 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.087 1.504 8.470
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 1.135 1.503 8.531
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.152 1.521 8.569
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.140 1.539 8.581
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.201 0.857 0.655 4.843 0.000 kW
0.869 kWh
0.000 kW
3.474 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.202 0.880 0.726 5.054
14 - 202216****** IQ7+ [0] ---- 0.000 0.203 0.877 0.724 5.094
15 - 202245****** IQ7+M [0] ---- 0.000 0.198 0.860 0.695 4.919
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.