Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.310 kW
07/03/2026 06:55 (2228 days) Production Consumption NET Usage
Now 0.629 kW 2.939 kW 2.310 kW
Today 1.837 kWh (0.264 kW) 10.556 kWh (1.518 kW) 8.719 kWh (1.254 kW)
  - This Week 144.711 kWh (27.361 kWh/day) 170.694 kWh (32.274 kWh/day) 25.983 kWh (4.913 kWh/day)
  - This Month 63.110 kWh (27.564 kWh/day) 96.554 kWh (42.171 kWh/day) 33.444 kWh (14.607 kWh/day)
  - This Year 3.673 MWh (20.039 kWh/day) 3.383 MWh (18.459 kWh/day) -0.290 MWh (-1.580 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 173.471 kWh (24.782 kWh/day) 204.634 kWh (29.233 kWh/day) 31.163 kWh (4.452 kWh/day)
Last 30 Days (06/03/2026) 862.903 kWh (28.763 kWh/day) 794.811 kWh (26.494 kWh/day) -68.092 kWh (-2.270 kWh/day)
Last One Year 6.716 MWh (18.400 kWh/day) 7.750 MWh (21.233 kWh/day) 1.034 MWh (2.833 kWh/day)
Lifetime Since PTO 39.239 MWh (17.609 kW/day) 42.894 MWh (19.250 kW/day) 3.655 MWh (1.640 kW/day)
Lifetime Since Install 39.273 MWh 43.474 MWh 4.202 MWh
Voltage/Current 249.0 V / 2.5 A 249.0 V / 11.8 A 249.0 V / 9.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/05/2023 23:13 (11.9 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.412 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.068 0.359 1.606 12.292 0.000 kW
0.343 kWh
0.000 kW
2.058 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.065 0.334 1.538 11.818
03 - 202224****** IQ7+M [5] VCOP 0.000 0.069 0.356 1.613 12.290
04 - 202232****** IQ7+ [5] VCOP 0.000 0.069 0.352 1.638 12.368
05 - 202244****** IQ7+M [5] VCOP 0.000 0.062 0.324 1.470 11.449
06 - 202245****** IQ7+M [5] VCOP 0.000 0.065 0.333 1.495 11.622
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.059 0.323 1.470 11.888 0.000 kW
0.326 kWh
0.000 kW
1.632 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.061 0.326 1.572 12.419
09 - 202217****** IQ7+ [5] VCOP 0.000 0.061 0.329 1.565 12.283
10 - 202244****** IQ7+M [5] VCOP 0.000 0.062 0.329 1.569 12.569
11 - 202224****** IQ7+M [5] VCOP 0.000 0.062 0.325 1.586 12.688
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.063 0.317 1.420 9.540 0.000 kW
0.356 kWh
0.000 kW
1.422 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.068 0.347 1.464 9.730
14 - 202216****** IQ7+ [5] VCOP 0.000 0.070 0.379 1.517 10.240
15 - 202245****** IQ7+M [5] VCOP 0.000 0.072 0.378 1.519 10.213
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.433 kWh
0.000 kW
1.300 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.237 1.300 2.264 17.443
Panel Layout Each Group Production

Battery History
Voltage 53.12 V Current/Power -3.76 A (-0.200 kW)
Remain Capacity/Energy 433.8 Ah (22.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 72.3 % State Of Health 100.0 %
Run Time 4d 19h 22m to empty Report Date 2023-04-05 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.