Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.770 kW
07/03/2026 08:41 (2228 days) Production Consumption NET Usage
Now 1.314 kW 0.544 kW -0.770 kW
Today 3.456 kWh (0.397 kW) 13.908 kWh (1.597 kW) 10.452 kWh (1.200 kW)
  - This Week 146.330 kWh (27.290 kWh/day) 174.046 kWh (32.459 kWh/day) 27.716 kWh (5.169 kWh/day)
  - This Month 64.729 kWh (27.397 kWh/day) 99.906 kWh (42.286 kWh/day) 35.177 kWh (14.889 kWh/day)
  - This Year 3.675 MWh (20.040 kWh/day) 3.387 MWh (18.470 kWh/day) -0.288 MWh (-1.570 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 174.393 kWh (24.913 kWh/day) 207.742 kWh (29.677 kWh/day) 33.349 kWh (4.764 kWh/day)
Last 30 Days (06/03/2026) 862.584 kWh (28.753 kWh/day) 796.115 kWh (26.537 kWh/day) -66.469 kWh (-2.216 kWh/day)
Last One Year 6.716 MWh (18.401 kWh/day) 7.751 MWh (21.236 kWh/day) 1.035 MWh (2.834 kWh/day)
Lifetime Since PTO 39.240 MWh (17.609 kW/day) 42.897 MWh (19.251 kW/day) 3.657 MWh (1.641 kW/day)
Lifetime Since Install 39.274 MWh 43.477 MWh 4.203 MWh
Voltage/Current 248.0 V / 5.3 A 248.0 V / 2.2 A 248.0 V / -3.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/16/2023 23:25 (10.1 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.068 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.151 0.573 1.360 8.016 0.000 kW
0.556 kWh
0.000 kW
3.335 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.148 0.544 1.312 7.628
03 - 202224****** IQ7+M [5] VCOP 0.000 0.152 0.573 1.346 7.828
04 - 202232****** IQ7+ [5] VCOP 0.000 0.150 0.559 1.335 7.623
05 - 202244****** IQ7+M [5] VCOP 0.000 0.147 0.542 1.339 7.773
06 - 202245****** IQ7+M [5] VCOP 0.000 0.148 0.543 1.310 7.627
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.156 0.488 1.434 8.212 0.000 kW
0.529 kWh
0.000 kW
2.646 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.157 0.536 1.544 8.893
09 - 202217****** IQ7+ [5] VCOP 0.000 0.159 0.541 1.589 9.299
10 - 202244****** IQ7+M [5] VCOP 0.000 0.158 0.548 1.587 9.266
11 - 202224****** IQ7+M [5] VCOP 0.000 0.157 0.533 1.583 9.031
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.124 0.524 0.695 4.415 0.000 kW
0.522 kWh
0.000 kW
2.087 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.124 0.519 0.752 4.728
14 - 202216****** IQ7+ [5] VCOP 0.000 0.126 0.529 0.757 4.747
15 - 202245****** IQ7+M [5] VCOP 0.000 0.124 0.515 0.735 4.623
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.38 V Current/Power -1.50 A (-78 W)
Remain Capacity/Energy 216.3 Ah (11.1 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 36.1 % State Of Health 100.0 %
Run Time 6d 0h 12m to empty Report Date 2023-02-16 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.