Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.491 kW
09/12/2025 20:57 (1934 days) Production Consumption NET Usage
Now 0.000 kW 0.491 kW 0.491 kW
Today 20.907 kWh (0.996 kW) 13.184 kWh (0.628 kW) -7.723 kWh (-0.368 kW)
  - This Week 126.394 kWh (21.518 kWh/day) 81.279 kWh (13.837 kWh/day) -45.115 kWh (-7.681 kWh/day)
  - This Month 263.322 kWh (22.177 kWh/day) 277.004 kWh (23.329 kWh/day) 13.682 kWh (1.152 kWh/day)
  - This Year 4.771 MWh (18.718 kWh/day) 5.448 MWh (21.374 kWh/day) 0.677 MWh (2.657 kWh/day)
Yesterday 26.396 kWh (1.101 kW) 14.540 kWh (0.606 kW) -11.856 kWh (-0.494 kW)
Last 7 Days 143.227 kWh (20.460 kWh/day) 158.213 kWh (22.601 kWh/day) 14.986 kWh (2.141 kWh/day)
Last 30 Days 685.205 kWh (22.841 kWh/day) 773.641 kWh (25.789 kWh/day) 88.436 kWh (2.948 kWh/day)
Last One Year 6.279 MWh (17.202 kWh/day) 7.076 MWh (19.386 kWh/day) 0.797 MWh (2.184 kWh/day)
Lifetime Since PTO 34.222 MWh (17.687 kW/day) 37.400 MWh (19.329 kW/day) 3.178 MWh (1.643 kW/day)
Lifetime Since Install 34.255 MWh 37.980 MWh 3.724 MWh
Voltage/Current 251.3 V / 0.0 A 251.2 V / 2.0 A 251.2 V / 2.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/26/2022 22:11 (12.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 7.777 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.188 0.547 0.866 11.721 0.000 kW
0.526 kWh
0.000 kW
3.157 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.135 0.506 0.836 11.095
03 - 202224****** IQ7+M [0] ---- 0.000 0.190 0.549 0.870 11.716
04 - 202232****** IQ7+ [0] ---- 0.000 0.188 0.531 0.866 11.478
05 - 202244****** IQ7+M [0] ---- 0.000 0.183 0.520 0.828 10.929
06 - 202245****** IQ7+M [0] ---- 0.000 0.164 0.504 0.825 11.035
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.203 0.494 0.770 11.118 0.000 kW
0.494 kWh
0.000 kW
2.471 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.200 0.497 0.776 11.105
09 - 202217****** IQ7+ [0] ---- 0.000 0.204 0.494 0.781 10.983
10 - 202244****** IQ7+M [0] ---- 0.000 0.141 0.488 0.790 11.208
11 - 202224****** IQ7+M [0] ---- 0.000 0.202 0.499 0.779 11.407
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.137 0.532 0.887 10.732 0.000 kW
0.537 kWh
0.000 kW
2.148 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.130 0.533 0.892 10.320
14 - 202216****** IQ7+ [0] ---- 0.000 0.141 0.546 0.908 10.838
15 - 202245****** IQ7+M [0] ---- 0.000 0.137 0.537 0.898 10.676
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.06 V Current/Power -5.36 A (-0.284 kW)
Remain Capacity/Energy 423.6 Ah (21.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 70.6 % State Of Health 100.0 %
Run Time 3d 7h 2m to empty Report Date 2022-04-26 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.