| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Exporting to grid by 0.671 kW | |||
|---|---|---|---|
| 07/03/2026 08:42 (2228 days) | Production | Consumption | NET Usage |
| Now | 1.324 kW | 0.653 kW | -0.671 kW |
| Today | 3.479 kWh (0.399 kW) | 13.919 kWh (1.595 kW) | 10.440 kWh (1.196 kW) |
| - This Week | 146.353 kWh (27.291 kWh/day) | 174.057 kWh (32.457 kWh/day) | 27.704 kWh (5.166 kWh/day) |
| - This Month | 64.752 kWh (27.398 kWh/day) | 99.917 kWh (42.277 kWh/day) | 35.165 kWh (14.879 kWh/day) |
| - This Year | 3.675 MWh (20.040 kWh/day) | 3.387 MWh (18.470 kWh/day) | -0.288 MWh (-1.570 kWh/day) |
| Yesterday | 35.642 kWh (1.485 kW) | 43.847 kWh (1.826 kW) | 8.205 kWh (0.342 kW) |
| Last 7 Days | 174.413 kWh (24.916 kWh/day) | 207.753 kWh (29.679 kWh/day) | 33.340 kWh (4.763 kWh/day) |
| Last 30 Days (06/03/2026) | 862.579 kWh (28.753 kWh/day) | 796.111 kWh (26.537 kWh/day) | -66.468 kWh (-2.216 kWh/day) |
| Last One Year | 6.716 MWh (18.401 kWh/day) | 7.751 MWh (21.235 kWh/day) | 1.034 MWh (2.834 kWh/day) |
| Lifetime Since PTO | 39.240 MWh (17.609 kW/day) | 42.897 MWh (19.251 kW/day) | 3.657 MWh (1.641 kW/day) |
| Lifetime Since Install | 39.274 MWh | 43.477 MWh | 4.203 MWh |
| Voltage/Current | 247.8 V / 5.3 A | 247.8 V / 2.6 A | 247.8 V / -2.7 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 02/13/2023 23:45 (10.4 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 18.731 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.270 | 1.367 | 0.597 | 6.955 | 0.000 kW 1.338 kWh |
0.000 kW 8.029 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.261 | 1.315 | 0.564 | 6.580 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.269 | 1.349 | 0.587 | 6.757 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.263 | 1.329 | 0.583 | 6.607 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.266 | 1.349 | 0.568 | 6.676 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.259 | 1.321 | 0.558 | 6.618 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.297 | 1.400 | 0.541 | 6.981 | 0.000 kW 1.511 kWh |
0.000 kW 7.557 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.297 | 1.515 | 0.557 | 7.618 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.303 | 1.570 | 0.560 | 8.010 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.298 | 1.555 | 0.565 | 7.970 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.304 | 1.518 | 0.546 | 7.680 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.150 | 0.754 | 0.545 | 4.101 | 0.000 kW 0.786 kWh |
0.000 kW 3.145 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.147 | 0.801 | 0.556 | 4.341 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.149 | 0.805 | 0.558 | 4.367 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.146 | 0.785 | 0.549 | 4.272 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122344****** | IQ7AS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.44 V | Current/Power | -1.17 A (-61 W) |
| Remain Capacity/Energy | 306.9 Ah (15.7 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 51.1 % | State Of Health | 100.0 % |
| Run Time | 10d 22h 18m to empty | Report Date | 2023-02-13 23:55 |
|
|||
| Voltage | 52.44 V | Cell (MIN/MAX) | 3.271 V / 3.283 V (0.012 V) |
|---|---|---|---|
| Current/Power | -0.39 A (-20 W) | Runtime | 11d 1h 42m to empty |
| Remain Capacity/Energy | 102.3 Ah (5.2 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 51.1 % | State Of Health | 100.0 % |
| Temperature | 18.0 °C | Cycle | 90 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-02-13 23:55 |
| Voltage | 52.44 V | Cell (MIN/MAX) | 3.277 V / 3.278 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 94.8 Ah (4.9 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 94.8 % | State Of Health | 100.0 % |
| Temperature | 18.0 °C | Cycle | 35 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-02-13 23:54 |
| Voltage | 52.46 V | Cell (MIN/MAX) | 3.277 V / 3.280 V (0.003 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 94.3 Ah (4.8 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 94.3 % | State Of Health | 100.0 % |
| Temperature | 19.5 °C | Cycle | 37 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-02-13 23:54 |
| Voltage | 52.43 V | Cell (MIN/MAX) | 3.275 V / 3.277 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 94.0 Ah (4.8 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 94.0 % | State Of Health | 100.0 % |
| Temperature | 20.7 °C | Cycle | 37 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-02-13 23:54 |
| Voltage | 52.43 V | Cell (MIN/MAX) | 3.275 V / 3.277 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 94.0 Ah (4.8 kWh) | Full Capacity/Energy | 99.7 Ah (5.1 kWh) |
| State Of Charge | 94.3 % | State Of Health | 99.7 % |
| Temperature | 18.8 °C | Cycle | 37 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-02-13 23:54 |