Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.756 kW
07/03/2026 09:49 (2228 days) Production Consumption NET Usage
Now 2.413 kW -1.343 kW -3.756 kW
Today 5.623 kWh (0.571 kW) 15.913 kWh (1.616 kW) 10.290 kWh (1.045 kW)
  - This Week 148.497 kWh (27.451 kWh/day) 176.051 kWh (32.545 kWh/day) 27.554 kWh (5.094 kWh/day)
  - This Month 66.896 kWh (27.757 kWh/day) 101.911 kWh (42.286 kWh/day) 35.015 kWh (14.529 kWh/day)
  - This Year 3.677 MWh (20.047 kWh/day) 3.389 MWh (18.476 kWh/day) -0.288 MWh (-1.570 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 175.918 kWh (25.131 kWh/day) 209.270 kWh (29.896 kWh/day) 33.352 kWh (4.765 kWh/day)
Last 30 Days (06/03/2026) 862.118 kWh (28.737 kWh/day) 797.322 kWh (26.577 kWh/day) -64.796 kWh (-2.160 kWh/day)
Last One Year 6.717 MWh (18.402 kWh/day) 7.752 MWh (21.239 kWh/day) 1.036 MWh (2.837 kWh/day)
Lifetime Since PTO 39.242 MWh (17.610 kW/day) 42.899 MWh (19.251 kW/day) 3.657 MWh (1.641 kW/day)
Lifetime Since Install 39.276 MWh 43.479 MWh 4.203 MWh
Voltage/Current 249.0 V / 9.7 A 249.0 V / -5.4 A 249.0 V / -15.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/18/2023 23:10 (9.1 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.960 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.254 0.634 0.345 3.715 0.000 kW
0.619 kWh
0.000 kW
3.711 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.245 0.592 0.321 3.526
03 - 202224****** IQ7+M [5] VCOP 0.000 0.255 0.637 0.340 3.716
04 - 202232****** IQ7+ [5] VCOP 0.000 0.250 0.625 0.330 3.675
05 - 202244****** IQ7+M [5] VCOP 0.000 0.251 0.619 0.329 3.607
06 - 202245****** IQ7+M [5] VCOP 0.000 0.241 0.603 0.318 3.566
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.289 0.775 0.267 3.805 0.000 kW
0.781 kWh
0.000 kW
3.904 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.287 0.760 0.326 4.123
09 - 202217****** IQ7+ [5] VCOP 0.000 0.291 0.790 0.327 4.274
10 - 202244****** IQ7+M [5] VCOP 0.000 0.286 0.791 0.333 4.290
11 - 202224****** IQ7+M [5] VCOP 0.000 0.286 0.788 0.313 4.066
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.124 0.318 0.303 2.107 0.000 kW
0.336 kWh
0.000 kW
1.344 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.148 0.342 0.301 2.283
14 - 202216****** IQ7+ [5] VCOP 0.000 0.149 0.345 0.307 2.293
15 - 202245****** IQ7+M [5] VCOP 0.000 0.145 0.341 0.301 2.237
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.23 V Current/Power -1.41 A (-75 W)
Remain Capacity/Energy 398.1 Ah (20.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 66.4 % State Of Health 100.0 %
Run Time 11d 18h 20m to empty Report Date 2023-01-18 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.