Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.162 kW
03/11/2026 20:14 (2114 days) Production Consumption NET Usage
Now 0.318 kW 0.480 kW 0.162 kW
Today 14.863 kWh (0.734 kW) 12.888 kWh (0.636 kW) -1.975 kWh (-0.098 kW)
  - This Week 74.785 kWh (19.457 kWh/day) 55.218 kWh (14.366 kWh/day) -19.567 kWh (-5.091 kWh/day)
  - This Month 168.493 kWh (15.539 kWh/day) 161.517 kWh (14.895 kWh/day) -6.976 kWh (-0.643 kWh/day)
  - This Year 0.802 MWh (11.489 kWh/day) 1.261 MWh (18.060 kWh/day) 0.459 MWh (6.571 kWh/day)
Yesterday 23.741 kWh (0.990 kW) 14.656 kWh (0.611 kW) -9.085 kWh (-0.379 kW)
Last 7 Days 88.234 kWh (12.605 kWh/day) 107.566 kWh (15.367 kWh/day) 19.332 kWh (2.762 kWh/day)
Last 30 Days (02/09/2026) 381.963 kWh (12.732 kWh/day) 495.884 kWh (16.529 kWh/day) 113.921 kWh (3.797 kWh/day)
Last One Year 6.039 MWh (16.545 kWh/day) 7.808 MWh (21.392 kWh/day) 1.769 MWh (4.847 kWh/day)
Lifetime Since PTO 36.368 MWh (17.197 kW/day) 40.772 MWh (19.279 kW/day) 4.404 MWh (2.082 kW/day)
Lifetime Since Install 36.402 MWh 41.352 MWh 4.950 MWh
Voltage/Current 249.9 V / 1.3 A 249.9 V / 1.9 A 249.9 V / 0.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/08/2022 21:59 (12.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.966 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.536 0.479 8.516 0.000 kW
1.486 kWh
0.000 kW
8.916 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.485 0.459 8.139
03 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.561 0.485 8.547
04 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.515 0.467 8.389
05 - 202244****** IQ7+M [0] ---- 0.000 0.298 1.432 0.461 8.009
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.386 0.459 7.891
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.298 1.438 0.430 8.049 0.000 kW
1.491 kWh
0.000 kW
7.454 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.504 0.433 8.201
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.461 0.431 8.017
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.523 0.432 8.305
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.527 0.434 8.289
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.273 1.412 0.467 7.604 0.000 kW
1.399 kWh
0.000 kW
5.597 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.274 1.387 0.475 7.436
14 - 202216****** IQ7+ [0] ---- 0.000 0.275 1.428 0.480 7.635
15 - 202245****** IQ7+M [0] ---- 0.000 0.276 1.369 0.465 7.374
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.73 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 280.8 Ah (14.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 46.8 % State Of Health 100.0 %
Run Time 7d 19h 12m to empty Report Date 2022-09-08 23:54
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.