Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.885 kW
07/03/2026 10:49 (2228 days) Production Consumption NET Usage
Now 3.213 kW 1.328 kW -1.885 kW
Today 8.440 kWh (0.778 kW) 16.126 kWh (1.487 kW) 7.686 kWh (0.709 kW)
  - This Week 151.314 kWh (27.758 kWh/day) 176.264 kWh (32.335 kWh/day) 24.950 kWh (4.577 kWh/day)
  - This Month 69.713 kWh (28.434 kWh/day) 102.124 kWh (41.653 kWh/day) 32.411 kWh (13.219 kWh/day)
  - This Year 3.680 MWh (20.057 kWh/day) 3.389 MWh (18.473 kWh/day) -0.291 MWh (-1.584 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 177.498 kWh (25.357 kWh/day) 207.989 kWh (29.713 kWh/day) 30.491 kWh (4.356 kWh/day)
Last 30 Days (06/03/2026) 861.730 kWh (28.724 kWh/day) 796.887 kWh (26.563 kWh/day) -64.843 kWh (-2.161 kWh/day)
Last One Year 6.717 MWh (18.402 kWh/day) 7.752 MWh (21.238 kWh/day) 1.035 MWh (2.836 kWh/day)
Lifetime Since PTO 39.245 MWh (17.611 kW/day) 42.900 MWh (19.251 kW/day) 3.654 MWh (1.640 kW/day)
Lifetime Since Install 39.279 MWh 43.480 MWh 4.201 MWh
Voltage/Current 247.9 V / 13.0 A 247.9 V / 5.4 A 247.9 V / -7.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/28/2022 23:00 (6.8 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.226 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.190 1.462 0.453 4.550 0.000 kW
1.454 kWh
0.000 kW
8.725 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.184 1.410 0.431 4.323
03 - 202224****** IQ7+M [5] VCOP 0.000 0.191 1.481 0.440 4.537
04 - 202232****** IQ7+ [5] VCOP 0.000 0.190 1.485 0.447 4.512
05 - 202244****** IQ7+M [5] VCOP 0.000 0.189 1.459 0.412 4.406
06 - 202245****** IQ7+M [5] VCOP 0.000 0.183 1.428 0.434 4.318
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.261 1.208 0.455 4.679 0.000 kW
1.455 kWh
0.000 kW
7.274 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.260 1.385 0.441 5.244
09 - 202217****** IQ7+ [5] VCOP 0.000 0.262 1.925 0.457 5.344
10 - 202244****** IQ7+M [5] VCOP 0.000 0.258 1.474 0.469 5.467
11 - 202224****** IQ7+M [5] VCOP 0.000 0.261 1.282 0.444 5.069
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.069 0.529 0.361 1.845 0.000 kW
0.557 kWh
0.000 kW
2.228 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.074 0.564 0.368 2.125
14 - 202216****** IQ7+ [5] VCOP 0.000 0.075 0.578 0.366 2.135
15 - 202245****** IQ7+M [5] VCOP 0.000 0.073 0.556 0.359 2.068
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.30 V Current/Power -1.65 A (-87 W)
Remain Capacity/Energy 462.9 Ah (23.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 77.1 % State Of Health 100.0 %
Run Time 11d 16h 32m to empty Report Date 2022-12-28 23:53
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack