Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.305 kW
09/13/2025 03:22 (1935 days) Production Consumption NET Usage
Now 0.000 kW 0.305 kW 0.305 kW
Today 0.000 kWh (0.000 kW) 1.289 kWh (0.381 kW) 1.289 kWh (0.381 kW)
  - This Week 126.394 kWh (20.582 kWh/day) 85.953 kWh (13.996 kWh/day) -40.441 kWh (-6.585 kWh/day)
  - This Month 263.322 kWh (21.689 kWh/day) 281.678 kWh (23.201 kWh/day) 18.356 kWh (1.512 kWh/day)
  - This Year 4.771 MWh (18.698 kWh/day) 5.452 MWh (21.370 kWh/day) 0.682 MWh (2.672 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.222 MWh (17.684 kW/day) 37.404 MWh (19.329 kW/day) 3.183 MWh (1.645 kW/day)
Lifetime Since Install 34.255 MWh 37.984 MWh 3.729 MWh
Voltage/Current 254.0 V / 0.0 A 253.9 V / 1.2 A 254.0 V / 1.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/10/2022 23:39 (10.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.251 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.264 1.034 1.398 5.468 0.000 kW
0.990 kWh
0.000 kW
5.940 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.257 0.958 1.314 5.090
03 - 202224****** IQ7+M [0] ---- 0.000 0.271 1.004 1.375 5.366
04 - 202232****** IQ7+ [0] ---- 0.000 0.266 0.952 1.332 5.266
05 - 202244****** IQ7+M [0] ---- 0.000 0.260 1.000 1.377 5.320
06 - 202245****** IQ7+M [0] ---- 0.000 0.257 0.993 1.337 5.229
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 1.109 1.639 5.982 0.000 kW
1.122 kWh
0.000 kW
5.612 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 0.948 1.477 5.355
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.213 1.744 6.393
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.191 1.711 6.315
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.151 1.675 6.139
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.154 0.663 0.703 3.287 0.000 kW
0.675 kWh
0.000 kW
2.699 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.160 0.677 0.761 3.452
14 - 202216****** IQ7+ [0] ---- 0.000 0.165 0.686 0.770 3.496
15 - 202245****** IQ7+M [0] ---- 0.000 0.157 0.673 0.757 3.436
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.70 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 249.6 Ah (12.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 41.6 % State Of Health 100.0 %
Run Time 6d 22h 24m to empty Report Date 2022-02-10 23:53
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.