Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.066 kW
03/11/2026 22:55 (2114 days) Production Consumption NET Usage
Now 0.317 kW 0.383 kW 0.066 kW
Today 15.716 kWh (0.685 kW) 14.224 kWh (0.620 kW) -1.492 kWh (-0.065 kW)
  - This Week 75.638 kWh (19.121 kWh/day) 56.554 kWh (14.296 kWh/day) -19.084 kWh (-4.824 kWh/day)
  - This Month 169.346 kWh (15.457 kWh/day) 162.853 kWh (14.865 kWh/day) -6.493 kWh (-0.593 kWh/day)
  - This Year 0.803 MWh (11.482 kWh/day) 1.263 MWh (18.050 kWh/day) 0.459 MWh (6.567 kWh/day)
Yesterday 23.741 kWh (0.990 kW) 14.656 kWh (0.611 kW) -9.085 kWh (-0.379 kW)
Last 7 Days 88.235 kWh (12.605 kWh/day) 106.598 kWh (15.228 kWh/day) 18.363 kWh (2.623 kWh/day)
Last 30 Days (02/09/2026) 381.112 kWh (12.704 kWh/day) 492.503 kWh (16.417 kWh/day) 111.391 kWh (3.713 kWh/day)
Last One Year 6.039 MWh (16.545 kWh/day) 7.808 MWh (21.391 kWh/day) 1.769 MWh (4.846 kWh/day)
Lifetime Since PTO 36.369 MWh (17.196 kW/day) 40.773 MWh (19.279 kW/day) 4.405 MWh (2.083 kW/day)
Lifetime Since Install 36.403 MWh 41.353 MWh 4.951 MWh
Voltage/Current 250.6 V / 1.3 A 250.6 V / 1.5 A 250.6 V / 0.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/21/2022 23:02 (14.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.574 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.809 1.942 10.851 0.000 kW
1.720 kWh
0.000 kW
10.321 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.707 1.808 10.242
03 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.755 1.868 10.581
04 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.746 1.874 10.484
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.598 1.704 9.849
06 - 202245****** IQ7+M [0] ---- 0.000 0.294 1.706 1.833 10.363
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 1.663 1.754 9.855 0.000 kW
1.638 kWh
0.000 kW
8.189 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.298 1.588 1.717 9.625
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.590 1.729 9.677
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.674 1.762 9.900
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.674 1.770 9.983
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.292 1.787 1.950 10.656 0.000 kW
1.766 kWh
0.000 kW
7.064 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.287 1.704 1.889 10.392
14 - 202216****** IQ7+ [0] ---- 0.000 0.290 1.796 1.948 10.701
15 - 202245****** IQ7+M [0] ---- 0.000 0.290 1.777 1.916 10.506
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.19 V Current/Power -4.70 A (-0.250 kW)
Remain Capacity/Energy 481.8 Ah (24.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 80.3 % State Of Health 100.0 %
Run Time 4d 6h 30m to empty Report Date 2022-07-21 23:50
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.