Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.733 kW
07/03/2026 12:43 (2228 days) Production Consumption NET Usage
Now 3.914 kW 2.181 kW -1.733 kW
Today 15.322 kWh (1.202 kW) 19.639 kWh (1.541 kW) 4.317 kWh (0.339 kW)
  - This Week 158.196 kWh (28.606 kWh/day) 179.777 kWh (32.508 kWh/day) 21.581 kWh (3.902 kWh/day)
  - This Month 76.595 kWh (30.266 kWh/day) 105.637 kWh (41.741 kWh/day) 29.042 kWh (11.476 kWh/day)
  - This Year 3.686 MWh (20.086 kWh/day) 3.392 MWh (18.484 kWh/day) -0.294 MWh (-1.602 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 181.530 kWh (25.933 kWh/day) 210.069 kWh (30.010 kWh/day) 28.539 kWh (4.077 kWh/day)
Last 30 Days (06/03/2026) 861.061 kWh (28.702 kWh/day) 799.485 kWh (26.649 kWh/day) -61.576 kWh (-2.053 kWh/day)
Last One Year 6.717 MWh (18.403 kWh/day) 7.752 MWh (21.239 kWh/day) 1.035 MWh (2.836 kWh/day)
Lifetime Since PTO 39.252 MWh (17.613 kW/day) 42.903 MWh (19.252 kW/day) 3.651 MWh (1.638 kW/day)
Lifetime Since Install 39.286 MWh 43.483 MWh 4.197 MWh
Voltage/Current 247.3 V / 15.8 A 247.3 V / 8.8 A 247.3 V / -7.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/29/2022 23:10 (10.2 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.893 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.237 1.382 1.066 5.183 0.000 kW
1.322 kWh
0.000 kW
7.934 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.232 1.281 0.998 4.933
03 - 202224****** IQ7+M [5] VCOP 0.000 0.236 1.323 1.058 5.201
04 - 202232****** IQ7+ [5] VCOP 0.000 0.236 1.286 1.021 5.024
05 - 202244****** IQ7+M [5] VCOP 0.000 0.236 1.337 1.045 5.122
06 - 202245****** IQ7+M [5] VCOP 0.000 0.230 1.325 1.021 5.005
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.283 1.417 1.000 5.177 0.000 kW
1.572 kWh
0.000 kW
7.862 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.286 1.558 1.088 5.563
09 - 202217****** IQ7+ [5] VCOP 0.000 0.283 1.654 1.151 5.772
10 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.623 1.167 5.788
11 - 202224****** IQ7+M [5] VCOP 0.000 0.282 1.610 1.114 5.627
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.143 0.735 0.773 3.491 0.000 kW
0.774 kWh
0.000 kW
3.097 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.142 0.789 0.776 3.628
14 - 202216****** IQ7+ [5] VCOP 0.000 0.144 0.802 0.787 3.658
15 - 202245****** IQ7+M [5] VCOP 0.000 0.143 0.772 0.767 3.535
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.