Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.738 kW
09/13/2025 10:18 (1935 days) Production Consumption NET Usage
Now 1.193 kW 0.455 kW -0.738 kW
Today 3.240 kWh (0.314 kW) 4.722 kWh (0.458 kW) 1.482 kWh (0.144 kW)
  - This Week 129.634 kWh (20.162 kWh/day) 89.386 kWh (13.902 kWh/day) -40.248 kWh (-6.260 kWh/day)
  - This Month 266.562 kWh (21.446 kWh/day) 285.111 kWh (22.939 kWh/day) 18.549 kWh (1.492 kWh/day)
  - This Year 4.774 MWh (18.690 kWh/day) 5.456 MWh (21.360 kWh/day) 0.682 MWh (2.670 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.225 MWh (17.683 kW/day) 37.408 MWh (19.328 kW/day) 3.183 MWh (1.645 kW/day)
Lifetime Since Install 34.259 MWh 37.988 MWh 3.729 MWh
Voltage/Current 252.3 V / 4.7 A 252.3 V / 1.8 A 252.3 V / -2.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/04/2022 22:58 (9.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.732 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.210 1.031 0.106 1.315 0.000 kW
1.005 kWh
0.000 kW
6.029 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.202 0.970 0.096 1.208
03 - 202224****** IQ7+M [5] VCOP 0.000 0.207 1.033 0.106 1.315
04 - 202232****** IQ7+ [5] VCOP 0.000 0.205 1.005 0.104 1.265
05 - 202244****** IQ7+M [5] VCOP 0.000 0.206 1.016 0.095 1.222
06 - 202245****** IQ7+M [5] VCOP 0.000 0.203 0.974 0.098 1.226
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.273 1.251 0.095 1.224 0.000 kW
1.228 kWh
0.000 kW
6.140 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.271 1.076 0.094 1.102
09 - 202217****** IQ7+ [5] VCOP 0.000 0.271 1.326 0.095 1.263
10 - 202244****** IQ7+M [5] VCOP 0.000 0.269 1.278 0.096 1.226
11 - 202224****** IQ7+M [5] VCOP 0.000 0.270 1.210 0.096 1.191
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.083 0.335 0.105 1.170 0.000 kW
0.391 kWh
0.000 kW
1.563 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.088 0.412 0.106 1.180
14 - 202216****** IQ7+ [5] VCOP 0.000 0.089 0.412 0.109 1.206
15 - 202245****** IQ7+M [5] VCOP 0.000 0.087 0.403 0.107 1.185
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.