Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.793 kW
07/03/2026 11:51 (2228 days) Production Consumption NET Usage
Now 3.686 kW 1.893 kW -1.793 kW
Today 12.035 kWh (1.013 kW) 17.828 kWh (1.500 kW) 5.793 kWh (0.487 kW)
  - This Week 154.909 kWh (28.194 kWh/day) 177.966 kWh (32.391 kWh/day) 23.057 kWh (4.196 kWh/day)
  - This Month 73.308 kWh (29.382 kWh/day) 103.826 kWh (41.614 kWh/day) 30.518 kWh (12.232 kWh/day)
  - This Year 3.683 MWh (20.072 kWh/day) 3.391 MWh (18.478 kWh/day) -0.293 MWh (-1.594 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 179.935 kWh (25.705 kWh/day) 209.291 kWh (29.899 kWh/day) 29.356 kWh (4.194 kWh/day)
Last 30 Days (06/03/2026) 861.406 kWh (28.714 kWh/day) 797.958 kWh (26.599 kWh/day) -63.448 kWh (-2.115 kWh/day)
Last One Year 6.717 MWh (18.403 kWh/day) 7.751 MWh (21.236 kWh/day) 1.034 MWh (2.833 kWh/day)
Lifetime Since PTO 39.249 MWh (17.612 kW/day) 42.901 MWh (19.251 kW/day) 3.653 MWh (1.639 kW/day)
Lifetime Since Install 39.283 MWh 43.481 MWh 4.199 MWh
Voltage/Current 248.3 V / 14.8 A 248.1 V / 7.6 A 248.2 V / -7.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/11/2022 23:33 (11.0 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.695 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.244 1.583 1.479 8.552 0.000 kW
1.525 kWh
0.000 kW
9.147 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.238 1.501 1.417 8.129
03 - 202224****** IQ7+M [5] VCOP 0.000 0.243 1.555 1.491 8.473
04 - 202232****** IQ7+ [5] VCOP 0.000 0.244 1.507 1.450 8.252
05 - 202244****** IQ7+M [5] VCOP 0.000 0.241 1.516 1.453 8.253
06 - 202245****** IQ7+M [5] VCOP 0.000 0.234 1.485 1.405 8.022
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.275 1.577 1.484 8.424 0.000 kW
1.705 kWh
0.000 kW
8.525 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.277 1.720 1.571 8.991
09 - 202217****** IQ7+ [5] VCOP 0.000 0.277 1.744 1.596 9.117
10 - 202244****** IQ7+M [5] VCOP 0.000 0.274 1.741 1.613 9.130
11 - 202224****** IQ7+M [5] VCOP 0.000 0.277 1.742 1.628 9.199
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.164 0.990 0.972 5.692 0.000 kW
1.006 kWh
0.000 kW
4.023 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.163 1.012 1.025 5.860
14 - 202216****** IQ7+ [5] VCOP 0.000 0.164 1.025 1.024 5.942
15 - 202245****** IQ7+M [5] VCOP 0.000 0.161 0.996 0.989 5.749
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary.png". Check that the process running PHP has enough permission.