| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Exporting to grid by 1.703 kW | |||
|---|---|---|---|
| 07/03/2026 13:48 (2228 days) | Production | Consumption | NET Usage |
| Now | 4.183 kW | 2.480 kW | -1.703 kW |
| Today | 19.438 kWh (1.406 kW) | 22.012 kWh (1.592 kW) | 2.574 kWh (0.186 kW) |
| - This Week | 162.312 kWh (29.113 kWh/day) | 182.150 kWh (32.671 kWh/day) | 19.838 kWh (3.558 kWh/day) |
| - This Month | 80.711 kWh (31.333 kWh/day) | 108.010 kWh (41.931 kWh/day) | 27.299 kWh (10.598 kWh/day) |
| - This Year | 3.691 MWh (20.104 kWh/day) | 3.395 MWh (18.493 kWh/day) | -0.296 MWh (-1.611 kWh/day) |
| Yesterday | 35.642 kWh (1.485 kW) | 43.847 kWh (1.826 kW) | 8.205 kWh (0.342 kW) |
| Last 7 Days | 183.223 kWh (26.175 kWh/day) | 212.118 kWh (30.303 kWh/day) | 28.895 kWh (4.128 kWh/day) |
| Last 30 Days (06/03/2026) | 860.474 kWh (28.682 kWh/day) | 799.187 kWh (26.640 kWh/day) | -61.287 kWh (-2.043 kWh/day) |
| Last One Year | 6.719 MWh (18.407 kWh/day) | 7.753 MWh (21.242 kWh/day) | 1.035 MWh (2.835 kWh/day) |
| Lifetime Since PTO | 39.256 MWh (17.615 kW/day) | 42.906 MWh (19.252 kW/day) | 3.649 MWh (1.638 kW/day) |
| Lifetime Since Install | 39.290 MWh | 43.486 MWh | 4.195 MWh |
| Voltage/Current | 247.2 V / 16.9 A | 247.2 V / 10.0 A | 247.2 V / -6.9 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 09/23/2022 21:31 (11.8 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 27.127 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.290 | 1.964 | 0.722 | 10.101 | 0.000 kW 1.902 kWh |
0.000 kW 11.409 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.283 | 1.877 | 0.681 | 9.677 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.289 | 1.967 | 0.727 | 10.112 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.285 | 1.917 | 0.685 | 9.883 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.286 | 1.885 | 0.694 | 9.661 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.280 | 1.799 | 0.684 | 9.439 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.297 | 1.874 | 0.786 | 9.725 | 0.000 kW 2.003 kWh |
0.000 kW 10.014 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.298 | 2.043 | 0.763 | 10.332 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.298 | 2.030 | 0.767 | 10.256 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.299 | 2.025 | 0.785 | 10.354 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.298 | 2.041 | 0.774 | 10.373 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.213 | 1.439 | 0.459 | 7.998 | 0.000 kW 1.426 kWh |
0.000 kW 5.704 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.212 | 1.408 | 0.451 | 7.960 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.213 | 1.461 | 0.478 | 8.071 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.209 | 1.397 | 0.454 | 7.873 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122344****** | IQ7AS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.18 V | Current/Power | -4.67 A (-0.248 kW) |
| Remain Capacity/Energy | 466.2 Ah (23.9 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 77.7 % | State Of Health | 100.0 % |
| Run Time | 4d 3h 49m to empty | Report Date | 2022-09-23 23:56 |
|
|||
| Voltage | 53.20 V | Cell (MIN/MAX) | 3.320 V / 3.329 V (0.009 V) |
|---|---|---|---|
| Current/Power | -1.43 A (-76 W) | Runtime | 4d 12h 22m to empty |
| Remain Capacity/Energy | 155.4 Ah (8.0 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 77.7 % | State Of Health | 100.0 % |
| Temperature | 25.0 °C | Cycle | 78 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-09-23 23:56 |
| Voltage | 53.16 V | Cell (MIN/MAX) | 3.321 V / 3.322 V (0.001 V) |
|---|---|---|---|
| Current/Power | -0.80 A (-42 W) | Runtime | 4d 19h 3m to empty |
| Remain Capacity/Energy | 92.0 Ah (4.7 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 92.0 % | State Of Health | 100.0 % |
| Temperature | 24.8 °C | Cycle | 28 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-09-23 23:55 |
| Voltage | 53.20 V | Cell (MIN/MAX) | 3.324 V / 3.326 V (0.002 V) |
|---|---|---|---|
| Current/Power | -0.85 A (-45 W) | Runtime | 4d 11h 57m to empty |
| Remain Capacity/Energy | 91.3 Ah (4.7 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 91.3 % | State Of Health | 100.0 % |
| Temperature | 25.4 °C | Cycle | 29 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-09-23 23:54 |
| Voltage | 53.15 V | Cell (MIN/MAX) | 3.321 V / 3.322 V (0.001 V) |
|---|---|---|---|
| Current/Power | -0.89 A (-47 W) | Runtime | 4d 7h 14m to empty |
| Remain Capacity/Energy | 91.6 Ah (4.7 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 91.6 % | State Of Health | 100.0 % |
| Temperature | 25.6 °C | Cycle | 29 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-09-23 23:53 |
| Voltage | 53.16 V | Cell (MIN/MAX) | 3.321 V / 3.323 V (0.002 V) |
|---|---|---|---|
| Current/Power | -0.84 A (-44 W) | Runtime | 4d 11h 55m to empty |
| Remain Capacity/Energy | 90.7 Ah (4.6 kWh) | Full Capacity/Energy | 99.7 Ah (5.1 kWh) |
| State Of Charge | 91.0 % | State Of Health | 99.7 % |
| Temperature | 24.7 °C | Cycle | 29 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-09-23 23:55 |