Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.617 kW
07/03/2026 15:44 (2228 days) Production Consumption NET Usage
Now 3.820 kW 2.203 kW -1.617 kW
Today 26.070 kWh (1.654 kW) 25.979 kWh (1.648 kW) -0.091 kWh (-0.006 kW)
  - This Week 168.944 kWh (29.870 kWh/day) 186.117 kWh (32.906 kWh/day) 17.173 kWh (3.036 kWh/day)
  - This Month 87.343 kWh (32.877 kWh/day) 111.977 kWh (42.150 kWh/day) 24.634 kWh (9.273 kWh/day)
  - This Year 3.697 MWh (20.131 kWh/day) 3.399 MWh (18.506 kWh/day) -0.298 MWh (-1.625 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 183.702 kWh (26.243 kWh/day) 214.212 kWh (30.602 kWh/day) 30.510 kWh (4.359 kWh/day)
Last 30 Days (06/03/2026) 859.197 kWh (28.640 kWh/day) 801.041 kWh (26.701 kWh/day) -58.156 kWh (-1.939 kWh/day)
Last One Year 6.719 MWh (18.409 kWh/day) 7.754 MWh (21.245 kWh/day) 1.035 MWh (2.835 kWh/day)
Lifetime Since PTO 39.263 MWh (17.617 kW/day) 42.910 MWh (19.254 kW/day) 3.647 MWh (1.636 kW/day)
Lifetime Since Install 39.297 MWh 43.489 MWh 4.193 MWh
Voltage/Current 246.9 V / 15.5 A 246.8 V / 8.9 A 246.9 V / -6.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/15/2022 21:43 (12.2 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.284 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.284 1.938 1.696 9.638 0.000 kW
1.881 kWh
0.000 kW
11.288 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.276 1.878 1.618 9.240
03 - 202224****** IQ7+M [5] VCOP 0.000 0.280 1.918 1.707 9.719
04 - 202232****** IQ7+ [5] VCOP 0.000 0.279 1.898 1.653 9.499
05 - 202244****** IQ7+M [5] VCOP 0.000 0.277 1.848 1.584 9.194
06 - 202245****** IQ7+M [5] VCOP 0.000 0.271 1.808 1.525 8.972
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 1.886 1.576 9.321 0.000 kW
1.984 kWh
0.000 kW
9.919 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 2.020 1.684 9.700
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.987 1.657 9.513
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 2.001 1.686 9.716
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.025 1.687 9.773
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.215 1.535 1.468 8.238 0.000 kW
1.519 kWh
0.000 kW
6.076 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.215 1.505 1.437 8.126
14 - 202216****** IQ7+ [5] VCOP 0.000 0.216 1.542 1.468 8.298
15 - 202245****** IQ7+M [5] VCOP 0.000 0.212 1.495 1.408 8.040
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.17 A (-62 W)
Remain Capacity/Energy 529.8 Ah (27.1 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 88.3 % State Of Health 100.0 %
Run Time 18d 20h 49m to empty Report Date 2022-09-15 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.