Date Offset  [+30][+10][+05][+01][-01][-05][-10]

Exporting to grid by 2.039 kW
07/01/2026 10:23 (2226 days) Production Consumption NET Usage
Now 2.650 kW 0.611 kW -2.039 kW
Today 4.652 kWh (0.447 kW) 8.853 kWh (0.851 kW) 4.201 kWh (0.404 kW)
  - This Week 86.253 kWh (25.124 kWh/day) 82.993 kWh (24.175 kWh/day) -3.260 kWh (-0.950 kWh/day)
  - This Month 4.652 kWh (10.727 kWh/day) 8.853 kWh (20.414 kWh/day) 4.201 kWh (9.687 kWh/day)
  - This Year 3.614 MWh (19.922 kWh/day) 3.296 MWh (18.164 kWh/day) -0.319 MWh (-1.757 kWh/day)
Yesterday 26.873 kWh (1.121 kW) 21.329 kWh (0.889 kW) -5.544 kWh (-0.231 kW)
Last 7 Days 170.497 kWh (24.357 kWh/day) 157.586 kWh (22.512 kWh/day) -12.911 kWh (-1.844 kWh/day)
Last 30 Days (06/01/2026) 873.809 kWh (29.127 kWh/day) 721.158 kWh (24.039 kWh/day) -152.651 kWh (-5.088 kWh/day)
Last One Year 6.696 MWh (18.345 kWh/day) 7.719 MWh (21.148 kWh/day) 1.023 MWh (2.803 kWh/day)
Lifetime Since PTO 39.180 MWh (17.598 kW/day) 42.806 MWh (19.226 kW/day) 3.626 MWh (1.629 kW/day)
Lifetime Since Install 39.214 MWh 43.386 MWh 4.172 MWh
Voltage/Current 248.9 V / 10.6 A 248.8 V / 2.5 A 248.8 V / -8.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 06/17/2026 23:54 (23.9 hours) Number of Devices 18 set
Current Power 0.321 kW (0.018 kW/panel) Today Energy 34.463 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.831 2.370 13.873 0.000 kW
1.724 kWh
0.000 kW
10.347 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.711 2.192 12.997
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.734 2.221 13.254
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.757 2.260 13.392
05 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.545 1.970 11.983
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.768 2.288 13.439
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.293 1.571 2.086 12.246 0.000 kW
1.595 kWh
0.000 kW
7.974 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.551 2.051 12.151
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.570 2.092 12.322
10 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.628 2.111 12.454
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.653 2.142 12.668
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.279 1.872 2.364 13.457 0.000 kW
1.925 kWh
0.000 kW
7.700 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.293 1.898 2.338 13.469
14 - 202216****** IQ7+ [5] VCOP 0.000 0.293 1.954 2.412 13.830
15 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.976 2.425 13.885
wind 16 - 202320****** IQ7XS [0] ---- 0.321 0.322 7.677 7.614 41.160 0.107 kW
2.814 kWh
0.321 kW
8.443 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.146 0.765 0.910 5.101
Panel Layout Each Group Production

Charger History
Voltage PV 1.21 V Voltage Charge 52.22 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.6 °C / 27.4 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2026-06-17 23:56
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.51 V Current/Power -7.85 A (-0.412 kW)
Remain Capacity/Energy 283.5 Ah (14.5 kWh) Full Capacity/Energy 548.1 Ah (28.1 kWh)
State Of Charge 51.7 % State Of Health 91.4 %
Run Time 1d 12h 6m to empty Report Date 2026-06-17 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.