Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.379 kW
07/03/2026 14:51 (2228 days) Production Consumption NET Usage
Now 2.651 kW 1.272 kW -1.379 kW
Today 23.012 kWh (1.546 kW) 24.029 kWh (1.615 kW) 1.017 kWh (0.068 kW)
  - This Week 165.886 kWh (29.521 kWh/day) 184.167 kWh (32.774 kWh/day) 18.281 kWh (3.253 kWh/day)
  - This Month 84.285 kWh (32.171 kWh/day) 110.027 kWh (41.997 kWh/day) 25.742 kWh (9.826 kWh/day)
  - This Year 3.694 MWh (20.118 kWh/day) 3.397 MWh (18.499 kWh/day) -0.297 MWh (-1.619 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 183.268 kWh (26.181 kWh/day) 212.995 kWh (30.428 kWh/day) 29.727 kWh (4.247 kWh/day)
Last 30 Days (06/03/2026) 859.657 kWh (28.655 kWh/day) 800.488 kWh (26.683 kWh/day) -59.169 kWh (-1.972 kWh/day)
Last One Year 6.719 MWh (18.409 kWh/day) 7.753 MWh (21.242 kWh/day) 1.034 MWh (2.833 kWh/day)
Lifetime Since PTO 39.260 MWh (17.616 kW/day) 42.908 MWh (19.253 kW/day) 3.648 MWh (1.637 kW/day)
Lifetime Since Install 39.294 MWh 43.488 MWh 4.194 MWh
Voltage/Current 246.9 V / 10.7 A 246.9 V / 5.2 A 246.9 V / -5.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/29/2022 22:08 (12.7 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.649 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.609 1.110 9.987 0.000 kW
1.571 kWh
0.000 kW
9.429 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.552 1.084 9.542
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.601 1.116 10.001
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.592 1.087 9.886
05 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.537 1.073 9.372
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.537 1.080 9.417
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 1.648 1.101 9.586 0.000 kW
1.648 kWh
0.000 kW
8.240 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.636 1.067 9.643
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.594 1.051 9.517
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.675 1.123 9.766
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.687 1.116 9.805
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.270 1.258 0.933 9.033 0.000 kW
1.245 kWh
0.000 kW
4.980 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.270 1.200 0.915 8.737
14 - 202216****** IQ7+ [5] VCOP 0.000 0.273 1.280 0.940 9.092
15 - 202245****** IQ7+M [5] VCOP 0.000 0.270 1.241 0.908 8.837
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.