Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.459 kW
09/13/2025 08:43 (1935 days) Production Consumption NET Usage
Now 1.293 kW 0.834 kW -0.459 kW
Today 0.821 kWh (0.094 kW) 3.566 kWh (0.408 kW) 2.745 kWh (0.314 kW)
  - This Week 127.215 kWh (19.989 kWh/day) 88.230 kWh (13.864 kWh/day) -38.985 kWh (-6.126 kWh/day)
  - This Month 264.143 kWh (21.364 kWh/day) 283.955 kWh (22.966 kWh/day) 19.812 kWh (1.602 kWh/day)
  - This Year 4.771 MWh (18.685 kWh/day) 5.455 MWh (21.360 kWh/day) 0.683 MWh (2.675 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.222 MWh (17.683 kW/day) 37.407 MWh (19.328 kW/day) 3.184 MWh (1.645 kW/day)
Lifetime Since Install 34.256 MWh 37.987 MWh 3.730 MWh
Voltage/Current 252.1 V / 5.1 A 252.1 V / 3.3 A 252.1 V / -1.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/01/2021 21:32 (10.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.585 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.264 1.106 0.985 5.206 0.000 kW
1.057 kWh
0.000 kW
6.341 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.253 1.012 0.933 4.890
03 - 202224****** IQ7+M [5] VCOP 0.000 0.264 1.060 0.985 5.181
04 - 202232****** IQ7+ [5] VCOP 0.000 0.261 1.012 0.940 4.993
05 - 202244****** IQ7+M [5] VCOP 0.000 0.261 1.092 0.973 5.069
06 - 202245****** IQ7+M [5] VCOP 0.000 0.258 1.060 0.917 4.919
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.394 1.082 5.441 0.000 kW
1.393 kWh
0.000 kW
6.965 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.333 0.950 5.083
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.432 1.127 5.611
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.389 1.115 5.557
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.417 1.091 5.481
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.177 0.525 0.644 3.755 0.000 kW
0.570 kWh
0.000 kW
2.279 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.177 0.583 0.664 3.842
14 - 202216****** IQ7+ [5] VCOP 0.000 0.179 0.592 0.673 3.898
15 - 202245****** IQ7+M [5] VCOP 0.000 0.179 0.579 0.662 3.833
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.19 V Current/Power -2.40 A (-0.128 kW)
Remain Capacity/Energy 486.6 Ah (24.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 81.1 % State Of Health 100.0 %
Run Time 8d 10h 44m to empty Report Date 2021-11-01 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.