Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.085 kW
01/14/2026 10:29 (2058 days) Production Consumption NET Usage
Now 0.231 kW 0.316 kW 0.085 kW
Today 0.555 kWh (0.053 kW) 2.851 kWh (0.271 kW) 2.296 kWh (0.219 kW)
  - This Week 37.880 kWh (11.020 kWh/day) 44.709 kWh (13.007 kWh/day) 6.829 kWh (1.987 kWh/day)
  - This Month 113.691 kWh (8.461 kWh/day) 243.443 kWh (18.116 kWh/day) 129.752 kWh (9.656 kWh/day)
  - This Year 0.114 MWh (8.461 kWh/day) 0.243 MWh (18.116 kWh/day) 0.130 MWh (9.656 kWh/day)
Yesterday 13.286 kWh (0.553 kW) 9.295 kWh (0.387 kW) -3.991 kWh (-0.166 kW)
Last 7 Days 66.655 kWh (9.522 kWh/day) 150.369 kWh (21.481 kWh/day) 83.714 kWh (11.959 kWh/day)
Last 30 Days 237.912 kWh (7.930 kWh/day) 604.721 kWh (20.157 kWh/day) 366.809 kWh (12.227 kWh/day)
Last One Year 6.105 MWh (16.725 kWh/day) 7.461 MWh (20.440 kWh/day) 1.356 MWh (3.715 kWh/day)
Lifetime Since PTO 35.679 MWh (17.333 kW/day) 39.755 MWh (19.313 kW/day) 4.076 MWh (1.980 kW/day)
Lifetime Since Install 35.713 MWh 40.335 MWh 4.622 MWh
Voltage/Current 250.6 V / 0.9 A 250.5 V / 1.3 A 250.5 V / 0.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/18/2022 22:47 (10.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.605 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.292 1.587 0.690 4.426 0.000 kW
1.538 kWh
0.000 kW
9.227 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.482 0.635 4.308
03 - 202224****** IQ7+M [5] VCOP 0.000 0.293 1.563 0.692 4.643
04 - 202232****** IQ7+ [5] VCOP 0.000 0.291 1.514 0.665 4.644
05 - 202244****** IQ7+M [5] VCOP 0.000 0.290 1.565 0.665 6.632
06 - 202245****** IQ7+M [5] VCOP 0.000 0.288 1.514 0.639 6.485
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.824 0.673 7.356 0.000 kW
1.805 kWh
0.000 kW
9.026 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.655 0.651 6.115
09 - 202217****** IQ7+ [5] VCOP 0.000 0.299 1.840 0.690 8.852
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.844 0.665 8.795
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.864 0.680 8.668
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.201 0.803 0.584 3.175 0.000 kW
0.838 kWh
0.000 kW
3.352 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.202 0.843 0.590 2.602
14 - 202216****** IQ7+ [5] VCOP 0.000 0.202 0.862 0.599 2.601
15 - 202245****** IQ7+M [5] VCOP 0.000 0.199 0.844 0.590 2.605
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.33 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 453.9 Ah (23.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 75.7 % State Of Health 100.0 %
Run Time 12d 14h 36m to empty Report Date 2022-02-18 23:54
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.