Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.211 kW
07/03/2026 14:53 (2228 days) Production Consumption NET Usage
Now 2.133 kW 0.922 kW -1.211 kW
Today 23.092 kWh (1.549 kW) 24.067 kWh (1.614 kW) 0.975 kWh (0.065 kW)
  - This Week 165.966 kWh (29.529 kWh/day) 184.205 kWh (32.774 kWh/day) 18.239 kWh (3.245 kWh/day)
  - This Month 84.365 kWh (32.188 kWh/day) 110.065 kWh (41.993 kWh/day) 25.700 kWh (9.805 kWh/day)
  - This Year 3.694 MWh (20.119 kWh/day) 3.397 MWh (18.499 kWh/day) -0.297 MWh (-1.619 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 183.276 kWh (26.182 kWh/day) 212.978 kWh (30.425 kWh/day) 29.702 kWh (4.243 kWh/day)
Last 30 Days (06/03/2026) 859.629 kWh (28.654 kWh/day) 800.517 kWh (26.684 kWh/day) -59.112 kWh (-1.970 kWh/day)
Last One Year 6.719 MWh (18.409 kWh/day) 7.753 MWh (21.242 kWh/day) 1.034 MWh (2.833 kWh/day)
Lifetime Since PTO 39.260 MWh (17.616 kW/day) 42.908 MWh (19.253 kW/day) 3.648 MWh (1.637 kW/day)
Lifetime Since Install 39.294 MWh 43.488 MWh 4.194 MWh
Voltage/Current 246.8 V / 8.6 A 246.7 V / 3.7 A 246.7 V / -4.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/02/2022 22:47 (13.9 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.771 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.818 0.604 10.198 0.000 kW
1.740 kWh
0.000 kW
10.438 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.722 0.572 9.535
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.773 0.607 9.916
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.785 0.591 9.889
05 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.611 0.583 9.026
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.730 0.580 9.643
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.687 0.558 9.185 0.000 kW
1.689 kWh
0.000 kW
8.446 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.668 0.473 9.058
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.667 0.500 8.990
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.696 0.563 9.209
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.726 0.580 9.313
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.279 1.753 0.536 10.368 0.000 kW
1.722 kWh
0.000 kW
6.887 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.274 1.682 0.527 10.139
14 - 202216****** IQ7+ [5] VCOP 0.000 0.280 1.760 0.549 10.393
15 - 202245****** IQ7+M [5] VCOP 0.000 0.287 1.692 0.540 10.210
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.17 V Current/Power -4.64 A (-0.247 kW)
Remain Capacity/Energy 502.8 Ah (25.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 83.8 % State Of Health 100.0 %
Run Time 4d 12h 21m to empty Report Date 2022-08-02 23:54
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.