Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.577 kW
07/03/2026 15:42 (2228 days) Production Consumption NET Usage
Now 3.824 kW 2.247 kW -1.577 kW
Today 25.931 kWh (1.649 kW) 25.898 kWh (1.647 kW) -0.033 kWh (-0.002 kW)
  - This Week 168.805 kWh (29.853 kWh/day) 186.036 kWh (32.901 kWh/day) 17.231 kWh (3.047 kWh/day)
  - This Month 87.204 kWh (32.844 kWh/day) 111.896 kWh (42.144 kWh/day) 24.692 kWh (9.300 kWh/day)
  - This Year 3.697 MWh (20.130 kWh/day) 3.399 MWh (18.506 kWh/day) -0.298 MWh (-1.625 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 183.563 kWh (26.223 kWh/day) 214.131 kWh (30.590 kWh/day) 30.568 kWh (4.367 kWh/day)
Last 30 Days (06/03/2026) 859.192 kWh (28.640 kWh/day) 800.987 kWh (26.700 kWh/day) -58.205 kWh (-1.940 kWh/day)
Last One Year 6.719 MWh (18.409 kWh/day) 7.754 MWh (21.245 kWh/day) 1.035 MWh (2.835 kWh/day)
Lifetime Since PTO 39.263 MWh (17.617 kW/day) 42.909 MWh (19.254 kW/day) 3.647 MWh (1.636 kW/day)
Lifetime Since Install 39.297 MWh 43.489 MWh 4.193 MWh
Voltage/Current 247.3 V / 15.5 A 247.1 V / 9.1 A 247.2 V / -6.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/31/2022 22:34 (13.7 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.316 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.752 1.945 11.048 0.000 kW
1.671 kWh
0.000 kW
10.027 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.622 1.808 10.362
03 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.702 1.876 10.762
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.724 1.853 10.683
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.558 1.708 9.819
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.669 1.824 10.449
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.601 1.773 10.053 0.000 kW
1.605 kWh
0.000 kW
8.025 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.625 1.718 9.827
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.586 1.711 9.815
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.604 1.775 10.088
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.609 1.808 10.179
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.294 1.830 1.978 10.985 0.000 kW
1.816 kWh
0.000 kW
7.264 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.290 1.792 1.878 10.656
14 - 202216****** IQ7+ [5] VCOP 0.000 0.296 1.839 1.968 10.997
15 - 202245****** IQ7+M [5] VCOP 0.000 0.289 1.804 1.916 10.800
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.17 V Current/Power -4.65 A (-0.247 kW)
Remain Capacity/Energy 572.4 Ah (29.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 95.4 % State Of Health 100.0 %
Run Time 5d 3h 6m to empty Report Date 2022-07-31 23:53
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.