Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.130 kW
01/14/2026 10:29 (2058 days) Production Consumption NET Usage
Now 0.234 kW 0.364 kW 0.130 kW
Today 0.553 kWh (0.053 kW) 2.847 kWh (0.271 kW) 2.294 kWh (0.219 kW)
  - This Week 37.878 kWh (11.021 kWh/day) 44.705 kWh (13.007 kWh/day) 6.827 kWh (1.986 kWh/day)
  - This Month 113.689 kWh (8.461 kWh/day) 243.439 kWh (18.116 kWh/day) 129.750 kWh (9.656 kWh/day)
  - This Year 0.114 MWh (8.461 kWh/day) 0.243 MWh (18.116 kWh/day) 0.130 MWh (9.656 kWh/day)
Yesterday 13.286 kWh (0.553 kW) 9.295 kWh (0.387 kW) -3.991 kWh (-0.166 kW)
Last 7 Days 66.655 kWh (9.522 kWh/day) 150.369 kWh (21.481 kWh/day) 83.714 kWh (11.959 kWh/day)
Last 30 Days 237.912 kWh (7.930 kWh/day) 604.721 kWh (20.157 kWh/day) 366.809 kWh (12.227 kWh/day)
Last One Year 6.105 MWh (16.725 kWh/day) 7.461 MWh (20.440 kWh/day) 1.356 MWh (3.715 kWh/day)
Lifetime Since PTO 35.679 MWh (17.333 kW/day) 39.755 MWh (19.313 kW/day) 4.076 MWh (1.980 kW/day)
Lifetime Since Install 35.713 MWh 40.335 MWh 4.622 MWh
Voltage/Current 250.5 V / 0.9 A 250.4 V / 1.5 A 250.4 V / 0.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/07/2022 22:16 (9.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.436 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.068 0.243 1.372 5.877 0.000 kW
0.234 kWh
0.000 kW
1.402 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.065 0.226 1.270 4.823
03 - 202224****** IQ7+M [5] VCOP 0.000 0.068 0.242 1.360 5.586
04 - 202232****** IQ7+ [5] VCOP 0.000 0.067 0.233 1.338 5.133
05 - 202244****** IQ7+M [5] VCOP 0.000 0.064 0.227 1.345 5.745
06 - 202245****** IQ7+M [5] VCOP 0.000 0.065 0.230 1.324 5.457
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.061 0.217 1.629 6.708 0.000 kW
0.215 kWh
0.000 kW
1.075 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.057 0.211 1.449 6.016
09 - 202217****** IQ7+ [5] VCOP 0.000 0.061 0.217 1.749 7.158
10 - 202244****** IQ7+M [5] VCOP 0.000 0.061 0.218 1.715 7.004
11 - 202224****** IQ7+M [5] VCOP 0.000 0.059 0.213 1.670 6.795
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.068 0.237 0.676 3.424 0.000 kW
0.240 kWh
0.000 kW
0.960 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.068 0.240 0.741 3.631
14 - 202216****** IQ7+ [5] VCOP 0.000 0.070 0.244 0.750 3.677
15 - 202245****** IQ7+M [5] VCOP 0.000 0.068 0.239 0.738 3.610
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.32 V Current/Power -1.50 A (-78 W)
Remain Capacity/Energy 124.5 Ah (6.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 20.8 % State Of Health 100.0 %
Run Time 3d 11h 0m to empty Report Date 2022-02-07 23:53
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.