Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.608 kW
11/08/2025 23:45 (1992 days) Production Consumption NET Usage
Now 0.000 kW 0.608 kW 0.608 kW
Today 15.394 kWh (0.647 kW) 24.394 kWh (1.026 kW) 9.000 kWh (0.379 kW)
  - This Week 93.095 kWh (13.318 kWh/day) 151.572 kWh (21.684 kWh/day) 58.477 kWh (8.366 kWh/day)
  - This Month 110.033 kWh (13.771 kWh/day) 167.760 kWh (20.995 kWh/day) 57.727 kWh (7.225 kWh/day)
  - This Year 5.688 MWh (18.231 kWh/day) 6.500 MWh (20.834 kWh/day) 0.812 MWh (2.603 kWh/day)
Yesterday 12.014 kWh (0.501 kW) 17.431 kWh (0.727 kW) 5.417 kWh (0.226 kW)
Last 7 Days 94.639 kWh (13.521 kWh/day) 143.366 kWh (20.482 kWh/day) 48.727 kWh (6.961 kWh/day)
Last 30 Days 404.420 kWh (13.481 kWh/day) 451.988 kWh (15.066 kWh/day) 47.568 kWh (1.586 kWh/day)
Last One Year 6.173 MWh (16.912 kWh/day) 7.473 MWh (20.473 kWh/day) 1.300 MWh (3.561 kWh/day)
Lifetime Since PTO 35.139 MWh (17.640 kW/day) 38.453 MWh (19.303 kW/day) 3.314 MWh (1.664 kW/day)
Lifetime Since Install 35.173 MWh 39.033 MWh 3.860 MWh
Voltage/Current 251.3 V / 0.0 A 251.3 V / 2.4 A 251.3 V / 2.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/04/2021 23:30 (9.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.024 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.225 1.020 1.159 6.168 0.000 kW
0.992 kWh
0.000 kW
5.953 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.220 0.955 1.054 5.734
03 - 202224****** IQ7+M [0] ---- 0.000 0.226 1.015 1.096 6.035
04 - 202232****** IQ7+ [0] ---- 0.000 0.224 0.993 1.068 5.821
05 - 202244****** IQ7+M [0] ---- 0.000 0.222 0.993 1.109 6.011
06 - 202245****** IQ7+M [0] ---- 0.000 0.219 0.977 1.090 5.834
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.264 1.068 1.306 6.838 0.000 kW
1.076 kWh
0.000 kW
5.378 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.264 0.953 1.121 6.260
09 - 202217****** IQ7+ [0] ---- 0.000 0.261 1.151 1.412 7.136
10 - 202244****** IQ7+M [0] ---- 0.000 0.249 1.121 1.393 7.022
11 - 202224****** IQ7+M [0] ---- 0.000 0.258 1.085 1.361 6.960
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.138 0.661 0.691 3.903 0.000 kW
0.673 kWh
0.000 kW
2.693 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.137 0.676 0.718 4.066
14 - 202216****** IQ7+ [0] ---- 0.000 0.141 0.685 0.725 4.120
15 - 202245****** IQ7+M [0] ---- 0.000 0.136 0.672 0.712 4.049
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.25 V Current/Power -1.80 A (-95 W)
Remain Capacity/Energy 413.1 Ah (21.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 68.8 % State Of Health 100.0 %
Run Time 9d 13h 30m to empty Report Date 2021-11-04 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.