Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.209 kW
03/09/2026 16:15 (2112 days) Production Consumption NET Usage
Now 2.716 kW 0.507 kW -2.209 kW
Today 21.816 kWh (1.341 kW) 8.153 kWh (0.501 kW) -13.663 kWh (-0.840 kW)
  - This Week 32.542 kWh (19.395 kWh/day) 20.623 kWh (12.291 kWh/day) -11.919 kWh (-7.104 kWh/day)
  - This Month 126.250 kWh (14.549 kWh/day) 126.922 kWh (14.626 kWh/day) 0.672 kWh (0.077 kWh/day)
  - This Year 0.760 MWh (11.232 kWh/day) 1.227 MWh (18.126 kWh/day) 0.467 MWh (6.894 kWh/day)
Yesterday 10.726 kWh (0.447 kW) 12.470 kWh (0.520 kW) 1.744 kWh (0.073 kW)
Last 7 Days 82.424 kWh (11.775 kWh/day) 106.243 kWh (15.178 kWh/day) 23.819 kWh (3.403 kWh/day)
Last 30 Days 384.891 kWh (12.830 kWh/day) 499.263 kWh (16.642 kWh/day) 114.372 kWh (3.812 kWh/day)
Last One Year 6.045 MWh (16.561 kWh/day) 7.790 MWh (21.341 kWh/day) 1.745 MWh (4.780 kWh/day)
Lifetime Since PTO 36.326 MWh (17.194 kW/day) 40.738 MWh (19.282 kW/day) 4.412 MWh (2.088 kW/day)
Lifetime Since Install 36.360 MWh 41.317 MWh 4.958 MWh
Voltage/Current 250.5 V / 10.8 A 250.5 V / 2.0 A 250.5 V / -8.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/12/2025 23:56 (21.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.577 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.070 0.252 0.320 8.844 0.000 kW
0.244 kWh
0.000 kW
1.463 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.066 0.238 0.302 8.450
03 - 202224****** IQ7+M [5] VCOP 0.000 0.069 0.249 0.318 8.735
04 - 202232****** IQ7+ [5] VCOP 0.000 0.070 0.249 0.316 8.781
05 - 202244****** IQ7+M [5] VCOP 0.000 0.065 0.233 0.294 8.378
06 - 202245****** IQ7+M [5] VCOP 0.000 0.068 0.242 0.308 8.535
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.061 0.229 0.289 8.726 0.000 kW
0.228 kWh
0.000 kW
1.141 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.062 0.227 0.289 9.420
09 - 202217****** IQ7+ [5] VCOP 0.000 0.061 0.228 0.289 9.569
10 - 202244****** IQ7+M [5] VCOP 0.000 0.062 0.230 0.292 9.636
11 - 202224****** IQ7+M [5] VCOP 0.000 0.062 0.227 0.289 9.707
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.063 0.226 0.289 5.630 0.000 kW
0.248 kWh
0.000 kW
0.990 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.068 0.241 0.308 5.963
14 - 202216****** IQ7+ [5] VCOP 0.000 0.070 0.261 0.325 6.174
15 - 202245****** IQ7+M [5] VCOP 0.000 0.070 0.262 0.327 6.162
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
2.492 kWh
0.000 kW
4.984 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.231 4.984 5.500 38.469
Panel Layout Each Group Production

Charger History
Voltage PV 1.58 V Voltage Charge 52.24 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.5 °C / 25.8 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-10-12 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.46 V Current/Power -2.10 A (-0.110 kW)
Remain Capacity/Energy 211.2 Ah (10.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 35.6 % State Of Health 98.9 %
Run Time 4d 4h 34m to empty Report Date 2025-10-12 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.