Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.609 kW
11/08/2025 22:39 (1991 days) Production Consumption NET Usage
Now 0.000 kW 0.609 kW 0.609 kW
Today 15.394 kWh (0.678 kW) 23.638 kWh (1.042 kW) 8.244 kWh (0.363 kW)
  - This Week 93.095 kWh (13.405 kWh/day) 150.816 kWh (21.717 kWh/day) 57.721 kWh (8.312 kWh/day)
  - This Month 110.033 kWh (13.849 kWh/day) 167.004 kWh (21.020 kWh/day) 56.971 kWh (7.171 kWh/day)
  - This Year 5.688 MWh (18.234 kWh/day) 6.499 MWh (20.835 kWh/day) 0.811 MWh (2.601 kWh/day)
Yesterday 12.014 kWh (0.501 kW) 17.431 kWh (0.727 kW) 5.417 kWh (0.226 kW)
Last 7 Days 94.639 kWh (13.521 kWh/day) 143.366 kWh (20.482 kWh/day) 48.727 kWh (6.961 kWh/day)
Last 30 Days 404.420 kWh (13.481 kWh/day) 451.988 kWh (15.066 kWh/day) 47.568 kWh (1.586 kWh/day)
Last One Year 6.173 MWh (16.912 kWh/day) 7.473 MWh (20.473 kWh/day) 1.300 MWh (3.561 kWh/day)
Lifetime Since PTO 35.139 MWh (17.640 kW/day) 38.452 MWh (19.303 kW/day) 3.313 MWh (1.663 kW/day)
Lifetime Since Install 35.173 MWh 39.032 MWh 3.859 MWh
Voltage/Current 251.1 V / 0.0 A 251.1 V / 2.4 A 251.1 V / 2.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/12/2021 17:23 (10.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.909 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.275 0.913 1.163 5.051 0.000 kW
0.885 kWh
0.000 kW
5.308 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.271 0.888 1.100 4.806
03 - 202224****** IQ7+M [0] ---- 0.000 0.276 0.905 1.170 5.061
04 - 202232****** IQ7+ [0] ---- 0.000 0.279 0.846 1.135 4.942
05 - 202244****** IQ7+M [0] ---- 0.000 0.273 0.881 1.136 4.852
06 - 202245****** IQ7+M [0] ---- 0.000 0.268 0.875 1.118 4.834
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.294 1.002 1.280 5.052 0.000 kW
0.994 kWh
0.000 kW
4.968 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.295 0.983 1.270 4.860
09 - 202217****** IQ7+ [0] ---- 0.000 0.298 0.988 1.281 5.102
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.000 1.264 5.117
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 0.995 1.281 5.100
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.179 0.645 0.783 4.147 0.000 kW
0.658 kWh
0.000 kW
2.633 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.182 0.660 0.797 4.177
14 - 202216****** IQ7+ [0] ---- 0.000 0.179 0.668 0.814 4.251
15 - 202245****** IQ7+M [0] ---- 0.000 0.178 0.659 0.796 4.179
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 54.55 V Current/Power 4.80 A (0.262 kW)
Remain Capacity/Energy 517.2 Ah (26.5 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 86.2 % State Of Health 100.0 %
Run Time 17h 14m to full Report Date 2021-10-12 18:03
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.