Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.202 kW
05/16/2026 04:03 (2180 days) Production Consumption NET Usage
Now 0.000 kW -0.202 kW -0.202 kW
Today 0.000 kWh (0.000 kW) 0.174 kWh (0.043 kW) 0.174 kWh (0.043 kW)
  - This Week 150.823 kWh (24.445 kWh/day) 75.821 kWh (12.289 kWh/day) -75.002 kWh (-12.156 kWh/day)
  - This Month 368.898 kWh (24.318 kWh/day) 192.958 kWh (12.720 kWh/day) -175.940 kWh (-11.598 kWh/day)
  - This Year 2.322 MWh (17.178 kWh/day) 2.253 MWh (16.666 kWh/day) -0.069 MWh (-0.512 kWh/day)
Yesterday 21.295 kWh (0.887 kW) 9.495 kWh (0.396 kW) -11.800 kWh (-0.492 kW)
Last 7 Days 160.422 kWh (22.917 kWh/day) 90.223 kWh (12.889 kWh/day) -70.199 kWh (-10.028 kWh/day)
Last 30 Days (04/16/2026) 683.846 kWh (22.795 kWh/day) 395.183 kWh (13.173 kWh/day) -288.663 kWh (-9.622 kWh/day)
Last One Year 6.338 MWh (17.364 kWh/day) 7.788 MWh (21.337 kWh/day) 1.450 MWh (3.972 kWh/day)
Lifetime Since PTO 37.888 MWh (17.378 kW/day) 41.763 MWh (19.156 kW/day) 3.876 MWh (1.778 kW/day)
Lifetime Since Install 37.922 MWh 42.343 MWh 4.422 MWh
Voltage/Current 250.5 V / 0.0 A 250.4 V / -0.8 A 250.4 V / -0.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/17/2022 22:15 (13.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.075 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.886 1.382 11.994 0.000 kW
1.827 kWh
0.000 kW
10.963 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.298 1.794 1.324 11.384
03 - 202224****** IQ7+M [0] ---- 0.000 0.301 1.887 1.390 12.063
04 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.882 1.342 11.876
05 - 202244****** IQ7+M [0] ---- 0.000 0.299 1.730 1.354 11.397
06 - 202245****** IQ7+M [0] ---- 0.000 0.298 1.784 1.327 11.203
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.299 1.744 1.349 11.538 0.000 kW
1.774 kWh
0.000 kW
8.869 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.298 1.773 1.319 11.674
09 - 202217****** IQ7+ [0] ---- 0.000 0.299 1.744 1.330 11.514
10 - 202244****** IQ7+M [0] ---- 0.000 0.298 1.777 1.377 11.788
11 - 202224****** IQ7+M [0] ---- 0.000 0.299 1.832 1.364 11.930
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.298 1.833 1.204 10.554 0.000 kW
1.811 kWh
0.000 kW
7.243 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.297 1.755 1.183 10.247
14 - 202216****** IQ7+ [0] ---- 0.000 0.295 1.841 1.224 10.654
15 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.814 1.210 10.493
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.