Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.372 kW
11/08/2025 20:56 (1991 days) Production Consumption NET Usage
Now 0.000 kW 0.372 kW 0.372 kW
Today 15.394 kWh (0.734 kW) 22.289 kWh (1.063 kW) 6.895 kWh (0.329 kW)
  - This Week 93.095 kWh (13.545 kWh/day) 149.467 kWh (21.746 kWh/day) 56.372 kWh (8.202 kWh/day)
  - This Month 110.033 kWh (13.975 kWh/day) 165.655 kWh (21.039 kWh/day) 55.622 kWh (7.064 kWh/day)
  - This Year 5.688 MWh (18.238 kWh/day) 6.498 MWh (20.836 kWh/day) 0.810 MWh (2.597 kWh/day)
Yesterday 12.014 kWh (0.501 kW) 17.431 kWh (0.727 kW) 5.417 kWh (0.226 kW)
Last 7 Days 94.639 kWh (13.521 kWh/day) 143.366 kWh (20.482 kWh/day) 48.727 kWh (6.961 kWh/day)
Last 30 Days 404.420 kWh (13.481 kWh/day) 451.988 kWh (15.066 kWh/day) 47.568 kWh (1.586 kWh/day)
Last One Year 6.173 MWh (16.912 kWh/day) 7.473 MWh (20.473 kWh/day) 1.300 MWh (3.561 kWh/day)
Lifetime Since PTO 35.139 MWh (17.641 kW/day) 38.451 MWh (19.303 kW/day) 3.312 MWh (1.663 kW/day)
Lifetime Since Install 35.173 MWh 39.031 MWh 3.858 MWh
Voltage/Current 250.9 V / 0.0 A 250.9 V / 1.5 A 250.9 V / 1.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/04/2021 21:28 (9.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 2.288 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.046 0.161 1.123 9.689 0.000 kW
0.156 kWh
0.000 kW
0.934 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.046 0.151 1.089 9.320
03 - 202224****** IQ7+M [0] ---- 0.000 0.046 0.161 1.112 9.623
04 - 202232****** IQ7+ [0] ---- 0.000 0.046 0.159 1.088 9.490
05 - 202244****** IQ7+M [0] ---- 0.000 0.045 0.149 1.070 9.260
06 - 202245****** IQ7+M [0] ---- 0.000 0.046 0.153 1.077 9.121
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.042 0.142 1.087 9.802 0.000 kW
0.142 kWh
0.000 kW
0.711 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.041 0.140 1.058 9.057
09 - 202217****** IQ7+ [0] ---- 0.000 0.042 0.143 1.114 9.976
10 - 202244****** IQ7+M [0] ---- 0.000 0.042 0.144 1.118 9.998
11 - 202224****** IQ7+M [0] ---- 0.000 0.043 0.142 1.112 9.990
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.045 0.158 0.968 7.520 0.000 kW
0.161 kWh
0.000 kW
0.643 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.046 0.160 0.962 7.428
14 - 202216****** IQ7+ [0] ---- 0.000 0.046 0.164 0.974 7.577
15 - 202245****** IQ7+M [0] ---- 0.000 0.047 0.161 0.958 7.432
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.