| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 2.125 kW | |||
|---|---|---|---|
| 07/04/2026 01:32 (2229 days) | Production | Consumption | NET Usage |
| Now | 0.226 kW | 2.351 kW | 2.125 kW |
| Today | 0.353 kWh (0.226 kW) | 1.527 kWh (0.978 kW) | 1.174 kWh (0.752 kW) |
| - This Week | 176.305 kWh (29.074 kWh/day) | 203.444 kWh (33.549 kWh/day) | 27.139 kWh (4.475 kWh/day) |
| - This Month | 94.704 kWh (30.902 kWh/day) | 129.304 kWh (42.192 kWh/day) | 34.600 kWh (11.290 kWh/day) |
| - This Year | 3.705 MWh (20.126 kWh/day) | 3.416 MWh (18.559 kWh/day) | -0.288 MWh (-1.567 kWh/day) |
| Yesterday | 33.078 kWh (1.378 kW) | 41.779 kWh (1.741 kW) | 8.701 kWh (0.363 kW) |
| Last 7 Days | 186.323 kWh (26.618 kWh/day) | 220.262 kWh (31.466 kWh/day) | 33.939 kWh (4.848 kWh/day) |
| Last 30 Days (06/04/2026) | 856.146 kWh (28.538 kWh/day) | 807.874 kWh (26.929 kWh/day) | -48.272 kWh (-1.609 kWh/day) |
| Last One Year | 6.724 MWh (18.421 kWh/day) | 7.758 MWh (21.255 kWh/day) | 1.034 MWh (2.834 kWh/day) |
| Lifetime Since PTO | 39.270 MWh (17.617 kW/day) | 42.927 MWh (19.258 kW/day) | 3.657 MWh (1.640 kW/day) |
| Lifetime Since Install | 39.304 MWh | 43.507 MWh | 4.203 MWh |
| Voltage/Current | 251.3 V / 0.9 A | 251.2 V / 9.4 A | 251.3 V / 8.5 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 05/18/2022 22:41 (14.2 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 31.995 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.299 | 2.273 | 2.151 | 10.476 | 0.000 kW 2.140 kWh |
0.000 kW 12.841 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 2.105 | 2.042 | 9.940 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 2.162 | 2.101 | 10.347 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.298 | 2.154 | 2.066 | 10.167 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.297 | 2.002 | 1.928 | 9.856 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 2.145 | 2.065 | 9.961 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.298 | 2.097 | 1.997 | 9.878 | 0.000 kW 2.075 kWh |
0.000 kW 10.376 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 2.018 | 1.925 | 9.679 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.297 | 2.009 | 1.937 | 9.736 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.298 | 2.110 | 1.978 | 9.852 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.297 | 2.142 | 2.041 | 10.039 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.280 | 2.241 | 2.195 | 10.010 | 0.000 kW 2.194 kWh |
0.000 kW 8.778 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.277 | 2.122 | 2.080 | 9.693 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.278 | 2.225 | 2.183 | 10.128 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.276 | 2.190 | 2.154 | 10.008 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122344****** | IQ7AS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.17 V | Current/Power | -4.22 A (-0.224 kW) |
| Remain Capacity/Energy | 499.2 Ah (25.6 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 83.2 % | State Of Health | 100.0 % |
| Run Time | 4d 22h 18m to empty | Report Date | 2022-05-18 23:56 |
|
|||
| Voltage | 53.15 V | Cell (MIN/MAX) | 3.317 V / 3.326 V (0.009 V) |
|---|---|---|---|
| Current/Power | -1.19 A (-63 W) | Runtime | 5d 19h 50m to empty |
| Remain Capacity/Energy | 166.4 Ah (8.5 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 83.2 % | State Of Health | 100.0 % |
| Temperature | 21.0 °C | Cycle | 64 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-05-18 23:56 |
| Voltage | 53.17 V | Cell (MIN/MAX) | 3.322 V / 3.323 V (0.001 V) |
|---|---|---|---|
| Current/Power | -0.70 A (-37 W) | Runtime | 5d 18h 40m to empty |
| Remain Capacity/Energy | 97.5 Ah (5.0 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 97.5 % | State Of Health | 100.0 % |
| Temperature | 20.9 °C | Cycle | 17 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-05-18 23:59 |
| Voltage | 53.21 V | Cell (MIN/MAX) | 3.325 V / 3.326 V (0.001 V) |
|---|---|---|---|
| Current/Power | -0.80 A (-42 W) | Runtime | 5d 1h 38m to empty |
| Remain Capacity/Energy | 97.1 Ah (5.0 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 97.1 % | State Of Health | 100.0 % |
| Temperature | 22.0 °C | Cycle | 17 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-05-18 23:56 |
| Voltage | 53.17 V | Cell (MIN/MAX) | 3.322 V / 3.323 V (0.001 V) |
|---|---|---|---|
| Current/Power | -0.80 A (-42 W) | Runtime | 5d 0h 32m to empty |
| Remain Capacity/Energy | 96.9 Ah (5.0 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 96.9 % | State Of Health | 100.0 % |
| Temperature | 22.2 °C | Cycle | 17 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-05-18 23:58 |
| Voltage | 53.18 V | Cell (MIN/MAX) | 3.322 V / 3.324 V (0.002 V) |
|---|---|---|---|
| Current/Power | -0.78 A (-41 W) | Runtime | 5d 4h 52m to empty |
| Remain Capacity/Energy | 96.9 Ah (5.0 kWh) | Full Capacity/Energy | 99.7 Ah (5.1 kWh) |
| State Of Charge | 97.2 % | State Of Health | 99.7 % |
| Temperature | 21.1 °C | Cycle | 18 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-05-18 23:56 |