Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.801 kW
11/08/2025 23:00 (1992 days) Production Consumption NET Usage
Now 0.000 kW 0.801 kW 0.801 kW
Today 15.394 kWh (0.668 kW) 23.870 kWh (1.036 kW) 8.476 kWh (0.368 kW)
  - This Week 93.095 kWh (13.378 kWh/day) 151.048 kWh (21.705 kWh/day) 57.953 kWh (8.328 kWh/day)
  - This Month 110.033 kWh (13.824 kWh/day) 167.236 kWh (21.011 kWh/day) 57.203 kWh (7.187 kWh/day)
  - This Year 5.688 MWh (18.233 kWh/day) 6.500 MWh (20.835 kWh/day) 0.812 MWh (2.602 kWh/day)
Yesterday 12.014 kWh (0.501 kW) 17.431 kWh (0.727 kW) 5.417 kWh (0.226 kW)
Last 7 Days 94.639 kWh (13.521 kWh/day) 143.366 kWh (20.482 kWh/day) 48.727 kWh (6.961 kWh/day)
Last 30 Days 404.420 kWh (13.481 kWh/day) 451.988 kWh (15.066 kWh/day) 47.568 kWh (1.586 kWh/day)
Last One Year 6.173 MWh (16.912 kWh/day) 7.473 MWh (20.473 kWh/day) 1.300 MWh (3.561 kWh/day)
Lifetime Since PTO 35.139 MWh (17.640 kW/day) 38.452 MWh (19.303 kW/day) 3.314 MWh (1.663 kW/day)
Lifetime Since Install 35.173 MWh 39.032 MWh 3.860 MWh
Voltage/Current 251.5 V / 0.0 A 251.6 V / 3.2 A 251.5 V / 3.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/30/2021 22:40 (12.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 17.960 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.264 1.260 0.545 9.506 0.000 kW
1.241 kWh
0.000 kW
7.445 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.260 1.228 0.530 8.006
03 - 202224****** IQ7+M [0] ---- 0.000 0.264 1.272 0.548 9.488
04 - 202232****** IQ7+ [0] ---- 0.000 0.270 1.261 0.543 9.545
05 - 202244****** IQ7+M [0] ---- 0.000 0.263 1.211 0.521 8.895
06 - 202245****** IQ7+M [0] ---- 0.000 0.264 1.214 0.529 8.551
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.290 1.272 0.498 9.087 0.000 kW
1.282 kWh
0.000 kW
6.409 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.290 1.270 0.495 9.013
09 - 202217****** IQ7+ [0] ---- 0.000 0.290 1.278 0.504 9.055
10 - 202244****** IQ7+M [0] ---- 0.000 0.294 1.291 0.508 9.210
11 - 202224****** IQ7+M [0] ---- 0.000 0.288 1.297 0.502 9.290
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.225 1.036 0.527 8.624 0.000 kW
1.027 kWh
0.000 kW
4.106 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.228 0.998 0.529 8.391
14 - 202216****** IQ7+ [0] ---- 0.000 0.227 1.046 0.535 8.682
15 - 202245****** IQ7+M [0] ---- 0.000 0.224 1.026 0.531 8.544
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.22 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 492.9 Ah (25.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 82.2 % State Of Health 100.0 %
Run Time 13d 16h 36m to empty Report Date 2021-08-30 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.